My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20165
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20165
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2019 2:44:08 PM
Creation date
5/28/2019 2:44:06 PM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-20165
Building Department - Name
LENNAR HOMES LLC
Address
3232 KRESTERBROOKE LN
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Y. <br /> FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 1551A1 sf ADS Carrier Builder Name: Lennar Homes 0086 <br /> Street: 3232 Kresterbrooke Lane Permit office: City of Ztphyrhills <br /> City,State,Zip: FL, Permit Number: 2O (9 <br /> Owner. Lennar Homes Jurisdiction: k}}"gg-Wt(a)b <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1497.3 sgft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1176.00 ftz <br /> b.Frame-Wood,Adjacent R=11.0 321.33 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ftz <br /> 4. Number of Bedrooms 3 d.N/A R= ftz <br /> 5. Is this a worst case? Yes 10.Ceiling Types(1555.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1555.00 ft2 <br /> 6. Conditioned floor area above grade(ftz) 1555 b.N/A R= ftZ <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftz <br /> 11.Ducts R ftz <br /> 7. Windows(104.3 sgft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 311 <br /> a. U-Factor: Dbl,U=0.54 55.00 ftz <br /> SHGC: SHGC=0.33 <br /> b. U-Factor: Dbl,U=0.58 33.33 ftz 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 24.0 SEER:15.50 <br /> c. U-Factor: Dbl,U=0.56 16.00 ftz <br /> SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a.Electric Heat Pump 24.0 HSPF:9.00 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.473 ft. <br /> Area Weighted Average SHGC: 0.322 14.Hot water systems <br /> 8. Floor Types (1555.0 sgft.) Insulation Area a.Electric Cap:40 gallonsEF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1555.00 ftz b. Conservation features <br /> b.N/A R= ftZ None <br /> c.N/A R= ftz 15.Credits Pstat <br /> Glass/Floor Area: 0.067 <br /> Total Proposed Modified Loads: 50.81 PASS <br /> Total Baseline Loads: 50.93 <br /> hereby certify that the plans and specifications covered by Review of the plans and .fiHE$xT� <br /> this calculation are in compliance with the Florida Energy specifications covered by this a p <br /> Code. calculation indicates compliance <br /> �wehl�Gl� with the Florida Energy Code. ti. rrrri '�•;%Y= ;;;•+ ti, o <br /> PREPARED BY: Before construction is completed <br /> DATE: this building will be inspected for <br /> compliance with Section 553.908 <br /> hereby certify that this building,as designed, is in compliance Florida Statutes. .� <br /> with the Florida Energy Code. <br /> OWNER/AGENT: f BUILDING OFFIC AL: <br /> DATE: DATE: <br /> 011(4 <br /> - Compliance requires certification the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accord ce with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.040 Qn for whole house. <br /> 7/25/2018 7:32 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.