My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20165
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20165
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2019 2:44:08 PM
Creation date
5/28/2019 2:44:06 PM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-20165
Building Department - Name
LENNAR HOMES LLC
Address
3232 KRESTERBROOKE LN
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT <br /> WALLS <br /> V# Ornt Adjacent Space Cavity Width Height Sheathing Framing Solar Below <br /> 1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 20 8 160.0 ft2 0 0.600000 0 <br /> 2 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 54 8 432.0 ft2 0 0.600000 0 <br /> 3 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 34 8 272.0 ft2 0 0.600000 0 <br /> 4 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 33 8 264.0 ft2 0 0.600000 0 <br /> _ 5 N=>NE Garage Frame-Wood Main 11 19 8 8 157.3 ft2 0.23 0.01 0 <br /> 6 W=>NW Garage Frame-Wood Main 11 20 6 8 164.0 ft2 0.23 0.01 0 <br /> _ 7 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 6 8 48.0 ft2 0 0.600000 0 <br /> DOORS <br /> # Ornt Door Type Space Storms U-Value Width Height Area <br /> Ft In Ft In <br /> 1 N=>NE Insulated Main None .2 3 6 8 20 ft2 <br /> 2 N=>NE Wood Main None .4 2 8 6 8 17.8 ft2 <br /> WINDOWS , <br /> Orientation shown is the entered orientation => changed to Worst Case. <br /> Wall Overhang <br /> V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening <br /> 1 N=>NE 1 Metal Low-E Double Yes 0.56 0.3 N 16.0 ft2 2 ft 0 in 0 ft 9 in Drapes/blinds None <br /> 2 E=>SE 2 Metal Law-E Double Yes 0.54 0.33 N 16.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None <br /> 3 S=>SW 3 Metal Low-E Double Yes 0.54 0.33 N 16.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None <br /> 4 S=>SW 7 Metal Low-E Double Yes 0.58 0.32 N 33.3 ft2 2 ft 0 in 0 ft 4 in Drapes/blinds None <br /> 5 S=>SW 3 Metal Low-E Double Yes 0.54 0.33 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None <br /> GARAGE <br /> # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation <br /> 1 408 ft2 408 ft2 40 ft 8 ft 1 <br /> INFILTRATION <br /> # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 <br /> 1 Wholehouse Proposed ACH(50) .000356 1451.3 79.68 149.84 .2649 7 <br /> HEATING SYSTEM <br /> # System Type Subtype Efficiency Capacity Block Ducts <br /> 1 Electric Heat Pump/ None HSPF:9 24 kBtu/hr 1 sys#1 <br /> 7/25/2018 7:32 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.