Laserfiche WebLink
Singe Family Dwelling <br /> Plan Review.Comments <br /> 1: RF:E. shall be'a minimum of 8" above the road elevation and an engineered site plan. <br /> 2.. Lots shall be graded.to.comply withR40Y.3 of the'F.B.C: <br /> „ <br /> 3. Compaction:test required.if 24"'or more of fill dirt is brought.in:ai any one place: <br /> 4.: Tie in survey required before pouring concrete. <br /> .5. Driveways require a R.O.W. use permit All 4:sides of.driveway thru the sidewalk shall have <br /> expansion material.- <br /> 6- All setbacks-shall be met., . <br /> 7. All property:markers shall be.uncovered and marked at time of first inspection: <br /> 8:. :All A.D.A. requirements shall be met.:. <br /> 9.. No.electric,plumbing, mechanical;,.or framing shall be covered without an:inspection.and <br /> approval first. . <br /> 10.-All Garages shall:comply with,section R302:6.of.the F.B.C:.(Fire S:eparation). <br /> I.:Appliances:shall not be installed in a location where subject to mechanical damage unless. : . <br /> protected by approved barriers. M303.4 of'the F.B:C. <br /> 12. Water heaters shall comply.with section P607.3 of the F.R.C: <br /> 13. Foundation supportsfor.�A/C.units,shallbe raised at least 3" above finished grade. M1308.1. <br /> 14. Return air in all.bedrooms. F.B.C. .M1620.4.: : . - <br /> 15. Smoke detectors are to be installed:in accordance:-with.R313:1 of theT.B.C. <br /> 16:All glazing requirements are to be in accordance with R308.4.of the-F.B.C. . <br /> 17. All means,of egress are to:be in accordance with R311:of the F:B.C., <br /> 18."Green gypsum.board shall not be used:as a backer.in:showers or tubs.R702.4:2 F.B.C. : <br /> 19. Combination-type AFCI breakers_are required at all.locations requiring an AFCI-type breaker. ; <br /> .20. Carbon'monoxide.alarms will-be required in new:constrU. .0 i that uses fossil-burning heating <br /> or appliances or an attached garage,: ,They shall be-installed in accordance with the F.B.C. <br /> 21. All plumbing,mechanical,.and.electric al shall be separate from unit to.unit: This includes all <br /> underground plurribing and electric: <br /> 22.. All M 16'.N.E:C: Codes.will be enforced. . <br /> 23.Ta.imer= Resistant Receptacles in accordance with 406.11-of the 2016 ME:C . <br /> 24: In accordance:with the Land Development:Codo lots shall be sodded before final-at least 10 . . <br /> feet around:the structure. -. <br /> 25. Blower door-test and blown in insulation card shall be provided before C:.O. . <br /> 26. A copy of the energy cacls shall-be with.permit at all times. <br /> 2Z. Cony of final insulation report shall be:provided with:permit before rnaL . <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act _ N.E.C.-National Electric Code(2011.) <br />