My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20166
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20166
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2019 2:44:56 PM
Creation date
5/28/2019 2:44:54 PM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-20166
Building Department - Name
LENNAR HOMES LLC
Address
3217 KRESTERBROOKE LN
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DABuilding and Const-mction.Services(BCS) <br /> JL I A- <br /> !SC <br /> COUNTY FLORIDA <br /> IV- i <br /> Blower Door Test Report Form <br /> Property Address: Unit <br /> Permit#: Testing Company Name* <br /> -2.01 Q4(10 <br /> Test Date. Tester Name: <br /> Teste Cert M Contact Phone: <br /> Email: J <br /> 402.4.1.2 Testing.Building envelope air tightness shall be demonstrated by Section 402.4.1.2 <br /> The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes <br /> per hour. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).As required by <br /> the Building Official,testing shall be conducted by an approved third party.A written report of the results of the test <br /> shall be signed by the party conducting the test(including Agency Name)and provided to the Building Official prior <br /> to Certificate of Occupancy issuance. Testing shall be performed at any time after creation of all scheduled <br /> penetrations of the building thermal envelope. <br /> During testing:(check to verify condition met) <br /> UdExterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended <br /> weather-stripping or other <br /> Ef Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond <br /> intended infiltration <br /> Interior doors,if installed at the time of the test,shall be open <br /> Id Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed <br /> 9 Heating and cooling systems,if installed at the time of the test,shall be turned off <br /> IdSupply and return registers,if installed at the time of the test,shall be fully open <br /> Vb Building volume(ft3) <br /> Q5o Airflow at 50 Pascal(CFM) <br /> ACHso Air changes per hour at 50 Pascal <br /> Q5o x 60—.* Vb = 5-s ACH5o (10 ACH minimum) <br /> Pass 16' Fail E-1 <br /> r7 Outside Air mechanically introduced to space(less than 3.0 ACH) <br /> I hereby certify that the above envelope leakage per, results demonstrate compliance <br /> with Florida Energy Code requirements in accordance With Section R402.4.1.2. <br /> ;L0 <br /> Signa 0 ester Date <br />
The URL can be used to link to this page
Your browser does not support the video tag.