ing e Family we ing <br /> Plan Review Comments <br /> -L F.F.E. shall be a rmnirnum of-8" above the road elevation and an.engineered site plan. <br /> . - <br /> 2. Lots-shall be graded.to.comply with'R401.3 of the F.R.C. <br /> 3. Compaction:test required.if 24" or more of fill dirt is brought in.at any one place: <br /> 4: 'Tie in survey required before pouring concrete.. <br /> 5. Driveways:require a R.O.W.use permit: All-4 sides of driveway thru the sidewalk shall have- <br /> expansion material: . <br /> 6.. All setbacks shall be met: <br /> .7. All.property:markers shall be.uncovered and'marked.at time of first.'inspection: <br /> 8: :All A.D.A. requirements shall be met.:'. <br /> 9. No.electric;plumbing, mechanical;,or framing shall be covered without an inspection.and <br /> approval first. <br /> 10. All Garages shall comply.with secton R302:6-ofthe F.B.C: Fire Separation . <br /> 11. Appliances shall not:be installed in-A location where subject to.mechanical damage unless. :. <br /> protected by approved.barriers: M303.4 of.the F.B:C <br /> 12. Water heaters shall comply with section P607, of the F.B-.C: <br /> 13. Foundation su orts for A/C.units.shall be raised-at-least 3'.' above finished ade. M 1308.i <br /> PP . gr . . <br /> . 14. Return air in all,:bedrooms..F.B.C. M1620.4 <br /> 15:-Smoke detectors'are to b,installed:in accordance:with R313.1-of the F.B.C. <br /> 16..All glazing requirements are:16 be'in accordance with R308.4.of the F.B.C. <br /> 17. All means of egress are to be in-accordance with R31_Lof the F:B.C. <br /> 18. `.`Green gypsum board"shall riot be used as a backer.in:showersor tubs. R702.4.2.F.B.C. <br /> 19. Combination-type-AA—'I breakers_are_required.at all locations requiring an AFCI,type breaker: <br /> 20. Carbon inonoxicle.alarms:will-be required in new:construction that uses fossil-burning heating <br /> or appliances or an attached garage. _They shall be installed in accordance with the F,B.C: <br /> 21. All plumbing, mechanical,�and:electrical shall:be separate from unit to:unit: This includes all <br /> underground:plumbing and electric. <br /> 22. All 2016 N.E.Q. Codes.will be enforced. <br /> .23:-Tamper=Resistant Receptacles 1n accordance with 406.11 of the 20l6 N.E:C . <br /> 24:.In accordance-with the Land.Development:Code, lots.shall be sodded before final at least 10 . . . <br /> feet around the structure.:: <br /> 25. Blower door test and blown iri insulation card shall beprovided before C:.O.. . <br /> 26 f1-copy ofthe energy caclssltall be with perfnit.at all times., <br /> 27.. Copy of finial insulation report shall be yrovided:with per»iit before:final <br /> F.F.E.-Finished Floor-Elevation <br /> F.B.C- Florida Building Code 6a'Edition. <br /> R.O.W.-Right of Way <br /> A.D:A.-Americans with.Disabilities Act N.E.C.-.National Electric Code(2011) <br />