Laserfiche WebLink
Single Family Dwelling <br /> Plan Review.Comments <br /> 1. F.F.E. shall be.a minimum.of 8. above.the road elevation:and an engineered site plan. <br /> 2.- Lots shall be graded to.comply with R401.3 of the F.B:.C. <br /> 3. ;Compactionwest required:if 24 or more of fill dirt is brought in:at any one place: . <br /> 4:- Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.Q..W.use permit:: All 4:sides of driveway.thru the sidewalk shall ha* <br /> expansion material: <br /> -6. All:setbacks-shall be met...- <br /> .7._ All property:markers shall be.uncovered and marked at time.of first.'inspection: <br /> 8. All A.D.A. requirements shall be met.. <br /> 9.. No:electric,plumbing, mechanical,.or fraining shall be covered without an,inspection and :. <br /> approval first. . . <br /> 10. All Garages shall comply.with.section R302:6 of,the F.B.C.(Fire Separation). <br /> 11.Appliances.shall not be installed in,,a location where subject to mechanical damage unless <br /> protected by approved barriers. M303..4 of the F.B:C <br /> 12. Water heaters shall comply:with section P607.3 of the F.B.C: <br /> 13. Foundation supports:for A/C units shall be raised at least 3" above finished grade. M1308.1. <br /> 14. Return air in all bedrooms..F.B.C. .MI620.4. <br /> 15: Smoke detectors are.to be installed-in accordance:with-R313.1 of theT.B.C. <br /> 16. All.glazing requirements are to be-in accordance with R308.4.of the F.B.C. <br /> 17. All means-of egress are to be in:accordance with R311 of the F.B.G. . <br /> 18. `.`Green gypsum board shall riot be used.as.a backer,in showers or tubs. R702.4:2.E.B.C. <br /> 19,Combination-type AFCI-breakers are,required;at all.locations requiring an AFCI type breaker: <br /> 20. Carbon-monoxide alarms:will.be required in new:construction that uses fossil-burning heatin <br /> q . g g . <br /> :or appliances or an attached garage.:_ They shall be,installed in accordance with.the F.B.C.. <br /> 21. All plumbing, mechanical,.and electrical shall be separate from unit to'unit: This includes all. <br /> underground plumbing and electric: <br /> 22.. All 2016.N.E.C. Codes.will be enforced. <br /> 23.,Tamper= Resistant Receptacles in accordance with 406.11 of the 2016 ME <br /> . .24.An accordance.with the Land:.Development:Code; lots shall be sodded before final at least 10 . <br /> feet around the structure. <br /> 25. Blower door test and blown in insulation card shall be provided before C:O: . <br /> 26-A cony of the energy cacls.shall be with p6wiffat all times.: . . <br /> 27. Copy of findl insulation renort shall be:piovided with:periiiit before.final <br /> F.F:E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6 h Edition <br /> R.O.W.-Right ofWay <br /> A.D.A.-Americans with Disabilities Act N.E:C. National Electric Code(2011.) <br />