My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20168
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20168
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/29/2019 6:37:02 AM
Creation date
5/29/2019 6:37:00 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-20168
Building Department - Name
LENNAR HOMES LLC
Address
3244 KRESTERBROOKE LN
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE:FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 1791131 sf ADS Carder Builder Name: Lennar Homes 0087 <br /> Street: 3244 Kresterbrooke Lane Permit office: City of ZephyrhiEs <br /> City,State,Zip: FL, Permit Number <br /> Owner Lennar Homes Jurisdiction: 611200 <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2 <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a-Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2 <br /> b.Frame-Wood,Adjacent R=1 1.0 331.33 ft2 <br /> 3. Number of units,if multiple family I c.N/A R= ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 10.Ceiling Types (1817.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1817.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft;t <br /> 11.Ducts R ft2 <br /> 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 <br /> a. U-Factor: Dbl,U=0.54 87.00 ft2 <br /> SHGC: SHGC=0.33 <br /> b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 28.4 SEER:15.00 <br /> c. U-Factor. Dbl,U=0.56 23.00 ft2 <br /> SHGC: SHGC=0.30 13.Heating systems kBtuthr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 28.2 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.233 ft. <br /> Area Weighted Average SHGC: 0.323 14.Hot water systems <br /> 8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features EF:0.950 <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Total Proposed Modified Loads: 57.78 <br /> Glass/Floor Area: 0.079 Total Baseline Loads: 58.15 PASS <br /> I hereby certify that the plans and specifications covered by Review of the plans and <br /> this calculation are in compliance with the Florida Energy specifications covered by this <br /> Code. calculation indicates compliance Zr Z <br /> with the Florida Energy Code. <br /> PREPARED BY: Dave AWich Before construction is completed <br /> DATE: this building will be inspected f :a. ..... <br /> or compliance with Section 553.908 <br /> I hereby certify that this building,as designed,is in compliance Florida Statutes. <br /> with the Florida Energy Code. <br /> OWNER/AGENT: BUILDING OFFICIAL: <br /> DATE: DATE: <br /> - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as <br /> certified factory�ealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with ANSIIRESNET/ICC 380,is not greater than 0.030 Qn for whole house. <br /> 7/25/2018 8:25 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.