My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20177
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20177
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2019 7:44:00 AM
Creation date
5/29/2019 6:42:00 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-20177
Building Department - Name
MATA,RICHAL & YEIMISOL
Address
6552 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7 a •ro <br /> DC RACEWAYS LABELING NOTES P-95689 <br /> Oi SEE NOTE N0.4 IOC RACEWAYS) O POINT-OF-INTERCONNECTION OR AT MAIN SERVICE DISCONNECT(UTILITY METER) ALL PLAQUES AND SIGNAGE REQUIRED BY 2014 NEC <br /> OAND 2015 NFPA 1 WILL BE INSTALLED AS REQUIRED. <br /> I CAUTION I LABELS,WARNING(S)AND MARKING SHALL COMPLY <br /> JB1-TRANSITION BOX VARNIN <br /> POWER TO THIS BUILDING ISALSO FROM ROOF MOUNTED SOUIRARRAY WITH SAFETY DISCONNECTS WITH ANSI Z535A,WHICH REQUIRES THAT DANGER, <br /> MODEL NOT SPECIFIED) , i .® AS SHOWN WARNING,AND CAUTION SIGNS USED THE STANDARD <br /> _ HEADER COLORS,HEADER TEXT,AND SAFETY ALERT <br /> O O :-'�- SYMBOL ON EACH LABEL.THE ANSI STANDARD <br /> R• REQUIRES A HEADING THAT IS AT LEAST 50%TALLER <br /> NEC 690.31(G)(3)AND IFC605.11.1 'ice THAN THE BODY TEXT,IN ACCORDANCE WITH NEC <br /> N 4 '; 110.21(B). <br /> 11-INVERTER 3 EACH DISCONNECTING MEANS FOR W <br /> 3-'a'm A PERMANENT PLAQUE OR DIRECTORY SHALL BE <br /> SOLAR EDGE SE7600H-US O PHOTOVOLTAIC EQUIPMENT(JB7,11) INSTALLED PROVIDING THE LOCATION OF THE SERVICE <br /> DISCONNECTING MEANS AND THE PHOTOVOLTAIC <br /> SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME U) <br /> 000 <br /> LOCATION IN ACCORDANCE WITH NEC 690.56(B). � W J <br /> ELECTRtCSHOCKHAZARD..1*140TTOUCH 0!� U <br /> SW1-DISCONNECT TERMINALS;TERMINALS ON BOTH LINE AND.' LABEL(S)WITH MARKING.'WARNING PHOTOVOLTAIC W Z <br /> POWER SOURCE;SHALL BE LOCATED AT EVERY 10 <br /> EATON DG222NRB LOAD SIDES MAYBE ENERWEDINTHE OPEN; _ FEET OF EACH DC RACEWAY AND WITHIN ONE FOOT OF � W ~ <br /> O O O NEC 690.17(E) 'POSITION.-,-' ":.,` EVERY TURN OR BEND AND WITHIN ONE FOOT ABOVE Q 0 Z <br /> fi 7 8 9 a T AND BELOW ALL PENETRATIONS OF ROOFICEILING Q <br /> ASSEMBLIES,WALLS AND BARRIERS.THE LABEL SHALL W Ur <br /> EACH DEVICE WHERE ENERGIZED, HAVE 318'TALL LETTERS AND BE REFLECTIVE WITHry <br /> r' Q <br /> 4 UNGROUNDED CIRCUITS MAY BE EXPOSED q� '�Y • WHITE TEXT ON A RED BACKGROUND Q <br /> UTILITY METER O DURING SERVICE.(JB7,11) ;�' - !I,` LABEL(S)WITH MARKING,"PHOTOVOLTAIC SYSTEM <br /> EQUIPPED WITH RAPID SHUTDOWN,'SHALL BE LOCATED C/) Q Lo <br /> O O t •, AT POINT-OF-INTERCONNECTION OR AT MAIN SERVICE <br /> ELECTRIC SHOCK HAZARD.THE DC" '� �' '' Lo <br /> v DISCONNECT THE LABEL SHALL HAVE 3/8'TALL Q <br /> b-�c r-s'i°" � ' LETTERS AND BE REFLECTIVE WITH WHITE TEXT ON A <br /> W <br /> CONOUCYORSOF,,,THISPHOTOVOLTAIC$YSTEM ;ae;..;tom, �., REDBACKGROUND <br /> ARE UNGROIiNDECtANp'NIAYBEENERGiZED. <br /> NEC 690.35(F) NEC 690.56(B) <br /> OOC DISCONNECT(11) O SEE NOTE NO.5(SW1) O AC DISCONNECT(SW1) <br /> II 71• <br /> NEC 690.53 NEC690.56(C)AND IFC605.11.1 NEC 690.54 <br /> OA V AC ELECTRICAL PANEL THAT IS FED BY <br /> BOTH THE UTILITY AND THE PHOTOVOLTAIC O AC SOLAR DISCONNECT(SW7) <br /> SYSTEM(SW1,UTILITY METER) <br /> !'WARMING'I . SAFETY LABELS <br /> DUAL POWER SOURCE:SECOND,SOURCE IS <br /> DOC ID:95689-119960-1 <br /> PHOTOVOLTAIbSYSTEM,,...';' <br /> DATE:8/23118 <br /> NEC 705.12(D)(3) NEC 690.13(B) CREATOR:S.S. <br /> REVIEWER: <br /> REVISIONS <br /> PV-4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.