My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20178
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20178
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2019 7:44:27 AM
Creation date
5/29/2019 6:43:15 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
18-20178
Building Department - Name
MELENDEZ,JEAN COLON
Address
5153 20TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
j A :2. FIRE SAFETY REQUIREMENTS P-95504 <br /> N EXTERIOR-MOUNTED DC CONDUITS,WIRING SYSTEMS, <br /> AND RACEWAYS FOR PHOTOVOLTAIC CIRCUITS SHALL <br /> 1 BE LOCATED AS CLOSEAS POSSIBLE TO THE RIDGE, <br /> HIP,OR VALLEY,AND FROM THE HIP OR VALLEY AS <br /> DIRECTLY AS POSSIBLE TO AN OUTSIDE WALL TO <br /> REDUCE TRIP HAZARDS AND MAXIMIZE VENTILATION <br /> OPPORTUNITIES(NFPA 111.12.2.2.4.1) <br /> ROOF ACCESS POINTS SHALL BE DEFINED AS AREAS <br /> WHERE FIRE DEPARTMENT LADDERS ARE NOT PLACED <br /> ^ OVER OPENINGS(WINDOWS OR DOORS),ARE LOCATED <br /> L AT STRONG POINTS OF BUILDING CONSTRUCTION,AND Lu <br /> .' ARE IN LOCATIONS WHERE THEY WILL NOT CONFLICT F-- <br /> ,$ WITH OVERHEAD OBSTRUCTIONS(TREE LIMBS,WIRES, (n <br /> 04 <br /> OR SIGNS).(NFPA 111.12.2.2.1.3) U <br /> - PHOTOVOLTAIC MODULES SHALL BE LOCATED IN A <br /> MANNER THAT PROVIDES TWO 3 FT WIDE ACCESS <br /> 3 PATHWAYS FROM THE EAVE TO THE RIDGE ON EACH W p ~ J <br /> ROOF SLOPE WHERE THE MODULES ARE LOCATED. U) <br /> ,. (NFPA 1 11.10.2.2.2.1.2) 3 fn LL <br /> _ PHOTOVOLTAIC MODULES SHALL BE LOCATED NO LESS N O J <br /> _ 4 THAN 3 FT BELOW THE RIDGE.(NFPA 111.10.2.2.2.2) J_ <br /> Q W co = <br /> O3.0 FT.WIDE FIRE ACCESS PATHWAY,PER NFPA 1 � L <br /> 11.10.2.2.2.1.2 L!J Ln _ <br /> 2O ROOF ACCESS POINT,PER NFPA 111.12.2.2.1.3 Q LJ <br /> LLI <br /> 4 O 3.0 FT.WIDE SMOKE-VENTILATION SETBACK,PER NFPA w IV <br /> 1 11.10.2.2.2,2 <br /> a 4 CABLES,WHEN RUN BETWEEN ARRAYS,SHALL BE !� <br /> - --- - ENCLOSED IN CONDUIT. <br /> 1 FIRE SAFETY PLAN 01 <br /> PV-7 SCALE:1'=20' <br /> FIRE SAFETY <br /> PLAN <br /> DOC ID:95504-119703.1 <br /> DATE,8121118 <br /> CREATOR:S.S. <br /> REVIEWER: <br /> REVISIONS <br /> PV-7 <br />