Laserfiche WebLink
ILI <br /> . , . . . , , APPROVAL <br /> SUPPTM <br /> GULFR . LY & MANUFACTURING <br /> 3 - <br /> g " <br /> 26 GUAGE GULFRIB TM PANEL OVER • • <br /> FLORIDA PRODUCT APPROVAL NO. 11651.22 R3 <br /> Compliance Statement: The product as described in this report has demonstrated compliance with the <br /> Florida Building Code 2017, Sections 1504.3.2. <br /> Product Description: GulfRibTM, 3/a" Rib Roof Panel, Minimum 26 Ga. Steel, 36" Coverage, <br /> through fastened roof panel over minimum 15/32" Plywood Decking. Non <br /> Structural application. <br /> Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to <br /> Florida Building Code 2017 Section 1507.4.3. <br /> Paint Finish Optional <br /> Yield Strength: Min. 80.Oksi <br /> Corrosion Resistance: Panel Material shall comply with Florida Building <br /> Code 2017, Section 1507.4.3. <br /> Panel Dimension(s): Thickness: 0.018" Minimum <br /> Width:' 36" Coverage <br /> Rib Height: 3/a" Major Rib at 9" O.C. <br /> Panel Fastener: #9-15x1.5" HWH with sealing washing or approved equal <br /> 1/4" minimum penetration through plywood. <br /> Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4 <br /> Substrate Description: Minimum 75/3z" thick,APA Rated plywood over supports at maximum 24" O.C. <br /> Design of plywood and plywood supports are outside the scope of this <br /> evaluation. Must be designed in accordance w/Florida Building Code 2017. <br /> Design Uplift Pressures: Table"A" <br /> ax u Tolls esi. ess ,e~ ,P$ ,` P <br /> Fastener Pattern 9"-9"-9"-9" 6.5"-2.5"-6.5"- <br /> 2.5"6.5"-2.5"-6.5" <br /> M* <br /> 1 _ <br /> Design Pressure includes a Safety Factor=2.0. <br /> FL#11651.22 R3•OCTOBER 5,2017 <br />