Laserfiche WebLink
FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> 0125 <br /> Project Name: 1551131 sf ADS Carrier Builder Name: Lennar Homes <br /> Street: 3241 Kresterbrooke Lane Permit Office: City of Zephyrhills <br /> City,State,Zip: FL, Permit Number: <br /> Owner. Lennar Homes Jurisdiction: 611200 <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1497.3 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1176.00 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 321.33 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 3 d.N/A R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1555.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1555.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 1555 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(104.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 311 <br /> a. U-Factor: Dbl,U=0.54 55.00 ft2 <br /> SHGC: SHGC=0.33 <br /> b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 24.0 SEER:15.50 <br /> c. U-Factor: Dbl,U=0.56 16.00 ft2 <br /> SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.319 ft. <br /> Area Weighted Average SHGC: 0.322 14.Hot water systems <br /> 8. Floor Types (1555.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> a.Slab-On-Grade Edge Insulation• R=0.0 1555.00 ft2 b. Conservation features EF:0.950 <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.067 Total Proposed Modified Loads: 50.96 PASS <br /> Total Baseline Loads: 50.93 <br /> hereby certify that the plans and specifications covered by Review of the plans and <br /> this calculation are in compliance with the Florida Energy specifications covered by this leo <br /> Code. calculation indicates compliance �,, ''� `'=z�:��. + <br /> with the Florida Energy Code. <br /> PREPARED BY: Dale A1.01pich Before construction is completed94 <br /> DATE: this building will be inspected for <br /> compliance with Section 553.908herebycertify that this building,as designed, is in compliance Florida Statutes. <br /> fY 9, 9 P <br /> with the Florida Energy Code. <br /> OWNER/AGENT: BUILDING OFFJCIAI <br /> DATE: DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.040 Qn for whole house. <br /> 7/25/2018 9:23 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 4 <br />