Laserfiche WebLink
Assembly Gross Area Cavity Cont. Proposed Budget U- <br /> or R-Value R-Value U-Factor Factor(a) <br /> Perimeter <br /> Door 4:Insulated Metal,Swinging,[Bldg.Use I -total net area] 21 --- 0.350 0.610 <br /> WEST <br /> Exterior Wall 2:Concrete Block:8",Solid Grouted,Medium Density, 1472 0.0 5.7 0.111 0.151 <br /> Furring:Wood,[Bldg.Use I -total net area] <br /> Door 5:Insulated Metal,Swinging,[Bldg.Use 1 -total net area] 21 --- --- 0.350 0.610 <br /> Door 6:Insulated Metal,Swinging,[Bldg.Use 1 -total net area] 21 0.350 0.610 <br /> Door 7:Insulated Metal,Swinging,[Bldg.Use I -total net area] 42 --- ... 0.350 0.610 <br /> (a)Budget U-factors are used for software baseline calculations ONLY,and are not code requirements. <br /> (b)Fenestration product performance must be certified in accordance with NFFIC and requires supporting documentation. <br /> (c)Slab-On-Grade proposed and budget U-factors shown in table are F-factors. <br /> 'Envelope PASSES-,De§jgn •' batter than code <br /> Envelope Compliance Statement <br /> Compliance Statement: The proposed envelope design represented In this document is consistent with the building plans, <br /> specifications,and other calculations submitted with this permit application.The proposed envelope systems have been <br /> designed to meet the 2017 Florida Building Code, Energy Consery,affon requirements i COMcheck Version 4.0.8.1 and to comply <br /> with any applicable mandatory requirements listed in the Ins i ecklis <br /> lee, d M-'t'45ke— 1-kC.4;1-e,-i- �7;? 7 <br /> Name Title SlVfature Date <br /> Project Title: Dollar General Shell Report date: 09/20/18 <br /> Data filename: D:\Dropbox 111Dropbox\LBM2018-ZH—Dollar-FL-Zephyrhills-WF\Dollar General Shell.cck Page 2'of 10 <br /> f <br />