My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-20634
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-20634
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2019 9:58:17 AM
Creation date
6/4/2019 7:17:24 AM
Metadata
Fields
Template:
Building Department
Company Name
DOLLAR GENERAL
Building Department - Doc Type
Permit
Permit #
19-20634
Building Department - Name
ZEPHYR II LLC
Address
5931 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EnCon Services, Inc. <br /> Sign Design Calculations <br /> Job Description PREPARED BY: EnCon Services, Inc. <br /> Dollar General PO Box 3613 <br /> 5931 Gall Blvd Apollo Beach, FL 33572 <br /> ,Zephyrhills, FL 33542 P 813-655-3373 <br /> 3-3 Raceway F 813-655-9814 <br /> Design per Florida Building Code,6th Edition(2017),Section 16 Wind Load, FLEB#9394 <br /> ASCE 7-10, Load Case: D+0.6W <br /> Design Specifications Nathan P. Presnell, PE <br /> Risk Category 11 FLPE 77696 <br /> Kzt 1 <br /> Exposure Factor C <br /> Kd 0.85 <br /> Kz 0.98 <br /> V 150 (mph) ```,��ryN111111f111/I/I!/���' <br /> GCp-GCpi 1.1 Zone 4, H<60 Feet ,O Q�N p••P/3�s <br /> --�� E <br /> Wind Pressure 52.8 (psf) � ,``:'•`,�G NSF'•y��G <br /> -;V: No 7769 <br /> Sign Information <br /> Height 3.25 ft • <br /> S TE OF <br /> Width Thickness 16.00 ftO••••.c•• ••.••�♦ ���;�� <ORI <br /> Distance grade to top 30 (ft) <br /> /1/1/t111111111� <br /> Wind Shear Force 102.92 (lb) <br /> Weight of Sign 538.85 (lb) DATE SIGNED: <br /> Total Shear Force= 548.59 (lb) 12/4/2018 <br /> .Total Tension Force= 1706.39 (lb) <br /> Required Provided <br /> Fastener size Nominal 3/8 3/8 <br /> Minimum number of fasteners 8 8 <br /> Shear Force per fastener(lb) 68.6 280 <br /> Tension Force per fastener Ib) 213.3 352 <br /> Combination Tension and 0.85 <1 O.K. <br /> Shear ratio <br /> THREADED ROD THROUGH WALL IS PREFERRED IN ALL INSTANCES. IF IT IS NOT POSSIBLE TO USE THREADED ROD,SEE CHART BELOW <br /> FOR APPROPRIATE ANCHOR SELECTION.SIZE AND NUMBER REQUIRED ARE NOTED IN THE CHART ABOVE. <br /> WALL STRUCTURE ANCHOR TYPE <br /> WOOD BLOCKING LAG BOLT(3'EMBEDMENT)THROUGH BLOCKING <br /> EIFS OVER 5/8".PLYWOOD LIBERTY TOGGLE BOLT OR THRU BOLT WITH SLEEVE <br /> HOLLOW CONCRETE BLOCK,BRICK SLEEVE ANCHOR(1-1/2'EMBEDMENT) <br /> SOLID CONCRETE WEDGE ANCHOR(2-1/2'EMBEDMENT) <br /> CMU,SOLID CONCRETE,BRICK HILTI HIT ROD W/HY-70 ADHESIVE(31/2'EMBEDMENT) <br /> ALL ANCHORS SHALL BE CHOSEN AND PLACED IN ACCORDANCE WITH MANUFACTURERS INSTALLATION INSTRUCTIONS <br /> 12/4/2018 <br /> Dollar General DG1530-2 Zephyrhills 3-3 Raceway E0061048 calc <br />
The URL can be used to link to this page
Your browser does not support the video tag.