Single Family Dwelling <br /> Plan Review Comments <br /> 1: F.F.E. shall be a mini_mum of.8" above.the road elevation-and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.R.C. <br /> 3. ,Compaction test required if 24" or more of fill dirt is brought in at anyone place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W. use permit: All 4 sides of driveway thru the sidewalk shall have. <br /> expansion material: <br /> 6. All setbacks shall be met. <br /> 7. All pro perty.markers shall be uncovered and marked at time of first inspection. <br /> 8. .All A.D.A. requirements shall be met.. <br /> 9. No electric; plumbing,mechanical; or framing shall be covered without an inspection and <br /> - approval first. <br /> =10. All.Garages shall comply with section R302:6 of the:F.B.C.(Fire Separation).. <br /> 11:Appliances shall not.be installed in a location where subject to.mechanical damage unless <br /> protected by approved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607,3 of the F.B.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M 1308.1 <br /> 14. Return air in-all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors are to be 'installed in accordance-with R313:1 of the F.B.C. <br /> 16:.All glazing requirements are to be in accordance with R308.4-of the F.B:C. <br /> 17. All means of egress are to be in accordance with R311:of the F.B.C. <br /> 18. "Green gypsum board' shall not be used as a backer.in showers or tubs. R702.4:2 F.B.C. <br /> 19. Combination-type AFCI breakers are required at all.locations requiring an AFCI type breaker: <br /> 20. Carbon monoxide alarms will be required in new.construction that uses fossil-burning heating <br /> or appliances or ari attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing, mechanical, and:electrical shall be separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 22. A112616.N.E.C: Codes will be enforced. <br /> 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E:C <br /> 24. In accordance with.the Land Development Code, lots shall be sodded before final at least 10 . <br /> feet around the structure. <br /> 25. Blower door test and blown in.irisulation card shall be provided before C.-O. <br /> 26 A copy of the energy cacls.shall be with permit-at all times. <br /> 27. Copy of final insulation i-eport shall be provided with:permit before ftnab <br /> 2& No fence:pool or screen enclosure is issued with this permit. <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C_ Florida Building Code Oh Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />