FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 1941 B1 sf ADS Carrier Builder Name: Lennar Homes 0093 <br /> Street: 3316 Kresterbrooke Lane Permit Office: City JZephyrhills <br /> City,State,Zip: FL, Permit Numbeg <br /> Owner: Lennar Homes Jurisdiction: <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 506.78 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 5: Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1936.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7..Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 309.76 <br /> a. U-Factor: Dbl,U=0.54 101.00 ft2 <br /> SHGC: SHGC=b.33 <br /> b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 23.00 ft2 <br /> SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.212 ft. <br /> Area Weighted Average SHGC: 0.323 14.Hot water systems <br /> 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:_40 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features EF:0.950 <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.081 Total Proposed Modified Loads: 62.62 PASS <br /> Total Baseline Loads: 62.90 <br /> I hereby certify that the plans and specifications covered by Review of the plans and <br /> this calculation are in compliance with the Florida Energy specifications covered by this <br /> Code. calculation indicates compliancewith the Florida Energy Code. ti' iwli' <br /> PREPARED BY: Dave AUnM Before construction is completed - -" <br /> DATE: this building will be inspected for a. 1, <br /> compliance with Section 553.908 ,* ° <br /> I hereby certify that this building,as designed, 's in compliance Florida Statutes. C, <br /> with the Florida Energy Code. <br /> OWNER/AGENT: 3 2018 BUILDING OFFICIAL: <br /> DATE: DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). <br /> - Compliance with a proposed duct leakage Qri requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. <br /> 7/26/2018 12:37 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 6 <br />