My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20404
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20404
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2019 7:22:31 AM
Creation date
6/4/2019 7:22:30 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-20404
Building Department - Name
LENNAR HOMES LLC
Address
3316 KRESTERBROOKE LN
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Men Buildings TaIg.We Listen <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING <br /> CONSTRUCTION <br /> Envelope Leakage Test Report <br /> Prescriptive and Performance Method <br /> Project Name: -14ORV 7.5 Builder Name: GEAuN.4P2 <br /> Street: Permit Office-, <br /> City, State,Zip: z eo <br /> Permit Number: 20al6q <br /> Design Location: Jurisdiction: <br /> Square Feet: 15'3e, Conditioned Volume: )63(po <br /> Envelope Leakage Test Results <br /> Single*Point Test Data: <br /> HOUSE PRESSURE: —156 FLOW: 165 11r <br /> Leakage Characteristics <br /> CFM (50): 2�pass D Fail <br /> ACH(50): 27 <br /> R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air <br /> changes per hour in Climate Zones I and 2 ... Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 <br /> Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals <br /> licensed as set forth in Section 489.105(3)(T�, (g), or(i) or an approved third party.A written report of the results of the test shall be <br /> signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all <br /> penetrations of the building thermal envelope. <br /> 1. Exterior windows and doors,fireplace and stove doors shall be closed, but not sealed,beyond the intended weatherstripping or other <br /> infiltration control measures; <br /> 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended <br /> infiltration control measures-, <br /> 3.Interior doors,if installed at the time of the test,shall be open; <br /> 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; <br /> 5.Heating and cooling systems,if installed at the time of the test,shall be turned off:and <br /> 6.Supply and return registers, if installed at the time of the test,shall be fully open <br /> hereby certify that the above envelope leakage Where required by the code official, testing shall be' <br /> )erformance results demonstrate compliance With conducted by an approved third-party. A written report of <br /> :lorida Energy Coder quirements in accordance with the 'Lest results shall be signed by the third party <br /> ;ection R402.4.1.2. conducting the test and provided to the code official. <br /> "IGNATURE: <br /> IRINTED NAME BUILDING OFFICIAL: <br /> )ATE: DATE: <br />
The URL can be used to link to this page
Your browser does not support the video tag.