Laserfiche WebLink
Manual S Compliance Report Job: 1941B1 sf ADS Carrier <br /> Date: 9/1712018 <br /> Entire House By: Dave <br /> Bayonet Plumbing Heating'and Air <br /> Rroj4d informa • <br /> For: Lennar Homes <br /> ® • i ng.- • • <br /> Design Conditions <br /> Outdoor design DB: 91XF Sensible gain: 26614 Btuh Entering coil DB: 75.6°F <br /> Outdoor design WB: 77.3°F Latent gain: 4080 Btuh Entering coil WB: 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 30694 Btuh <br /> Indoor RH: 50% Estimated airflow: 1200 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SplitASHP <br /> Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L <br /> Actual airflow: 1200 cfm <br /> Sensible capacity: 29580 Btuh 111% of load <br /> Latent capacity: 5220 Btuh 128% of load <br /> Total capacity: 34800 Btuh 113% of load SHR: 85% <br /> at n <br /> • • • <br /> Design Conditions <br /> Outdoor design DB: 30.8°F Heat loss: 29263 Btuh Entering coil DB: 69.7°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L <br /> Actual airflow: 1200 cfm <br /> Output capacity: 26331 - Btuh 90% of load Capacity balance: 28 °F <br /> Supplemental heat required: 2932 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: n/a Model: n/a+n/a <br /> Actual airflow: 1200 cfm <br /> Output capacity: 0 kW 0% of load Temp. rise: 0 °F <br /> Meets all requirements of ACCA Manual S. <br /> -Fk wrightsoft, 2018-Sep-1714:09:55 <br /> CA >.—��•,��M.,ona., Right-Suite® 9 <br /> Universal 2018 18.0.16 RSU05714 Page 1 <br /> Ar- ..equipment\1941 sf ADS template 3ton Carrierrup Calc=MJ8 Front Door faces:SW <br />