ing e aml .y we ,ing <br /> Plan Review Comments <br /> 1: _F.F.E. shall-�be a.minimum:of 8" above,the road.elevation and an engineered.site plan. <br /> 2. :Lots shall be graded,to comply with R401.3 of the F.B.C. <br /> 3.: ;Compaction test required if 24 or more of fill dirt is brought in:at any one place: - <br /> 4: Tie in.survey reguired before pouring concrete. <br /> 5.: Driveways:require a R;O:W. use permit. A114 sides of driveway thru the sidewalk shall Have. <br /> expansion material: <br /> 6.. All setbacks.shall be met.. <br /> .7.: All property:markers shall be uncovered and marked.at time of first.'inspection: <br /> 8.: All A.D.A.-requirements shall be met..'. <br /> 9.: Na electric,plumbing,.mechanical, or fframing shall be covered without an inspection and <br /> approval first. .. <br /> 10. All Garages shall:comply-with section R302:6.of the F.B.C.(Fire Separation).: <br /> 11.Appliances_shall riot.be installed in.a location'where subject to mechanical damage unless. <br /> protected:by approved barriers: M303.4 of the F.B.0 <br /> 12. Water heaters shall_comply with section:P607.3 of the F.B.C., <br /> 13. Foundation supports-for A/C units shall be raised at least 3'.' above finished grade.. M1308.-1 <br /> 14. Return-air in all.:bedrooms..F:B.C. .M1620.4.. <br /> 15. Smoke detectors are to be installeddn' ace6rdance:with R313:.1 of theT.B.C. <br /> .16.: All glazing requirements are:.to bein accordance with R308.4.of the F.B.C. <br /> 17. All means_of egress,are to be in accordance with R3 1 Y of the F:B.C. .. <br /> 18. `-"Green gypsum-board" shall not be used.a' s.a backer.in:showers or tubs. R702.4:2 F.B.C. <br /> 19. Combination-type AFCI breakers.are,required at all locations requiring an AFCI type breaker: . . <br /> 20. Carbon monoxide alarms will be required in.new construction that uses fossil-burning heating <br /> or appliances or an attached garage:_ They shalllie-installed in accordance with.the V.R.C. <br /> 21. Al_l plumbing, mechanical, and.electrical shall:be separate from unit to:unit: This includes all <br /> underground:plumbing and electric: <br /> 22. All 2016.N:E:C. Codes.will.be enforced:.' <br /> 23. Tamper-*Resistant Receptacles in accordance with 406.11-of the 2016 ME C <br /> .24.-An accordance:With the Land Development.Code;lots.shall be sodded before final at least 10 <br /> feet around the structure. . . <br /> 25._Blower door:test and blown in in-nsulation card shall be provided:before C:O: <br /> 26 A copy of the energy edels.shall be with permit at all times., <br /> 2Z. Copy of final insulation report shall be:provided with permit before.finab <br /> .28:No fence:pool or screen enclosure is issued with this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code Oh Edition <br /> R.O.W.-Right of . <br /> A:D.A:-Americans with Disabilities Act N.E.C.-:National Electric Code(2016) <br />