Search
18-20410
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20410
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2019 7:26:01 AM
Creation date
6/4/2019 7:25:59 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-20410
Building Department - Name
LENNAR HOMES LLC
Address
3292 KRESTERBROOKE LN
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> 0091 <br /> Project Name: 1941A1 sf ADS Carrier Builder Name: Lennar Homes <br /> Street: 3292 Kresterbrooke Lane Permit Office: City of Zephyrhills <br /> City,State,Zip: FL, Permit Number:J d 4/a <br /> Owner: Lennar Homes Jurisdiction: 6412()9`(QJ1 <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1119.8 sgft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1412.00 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 307.78 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sgft.) Insulation Area a.Under Attic(Vented) R=30.0 1936.00 ft2 <br /> 6. Conditioned floor area above grade(ft') 1936 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft') 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 <br /> a. U-Factor: Dbl,U=0.54 101.00 ft2 <br /> SHGC: SHGC=0.33 <br /> b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 23.00 ft2 <br /> SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.212 ft. <br /> Area Weighted Average SHGC: 0.323 14.Hot water systems <br /> 8. Floor Types (1936.0 sgft.) Insulation Area a.Electric Cap:40 gallons <br /> EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.081 Total Proposed Modified Loads: 61.68 PASS <br /> Total Baseline Loads: 61.53 <br /> I hereby certify that the plans and specifications covered by Review of the plans and D�,TI�E ST,g�� ' <br /> this calculation are in compliance with the Florida Energy specifications covered by this <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. f:. rrrrii�. . ;;: A,,,:``=� ,�0' <br /> Dave AGol�r'cGc <br /> PREPARED BY: Before construction is completed v <br /> DATE: this building will be inspected for 0. <br /> compliance with Section 553.908 * ' <br /> I hereby certify that this building,as design i Cin comp an g��yq Florida Statutes. <br /> with the Florida Energy Code. C� <br /> OWNER/AGENT: BUILDING OFFICIA <br /> DATE: DATE: <br /> - Compliance requires ce ' 'cation by the air handler unit manufacturer that the air handler en sure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 6.50 ACH50(R402.4.1.2). <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. <br /> 6/13/2018 1:36 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 6 <br />