My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20410
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20410
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2019 7:26:01 AM
Creation date
6/4/2019 7:25:59 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-20410
Building Department - Name
LENNAR HOMES LLC
Address
3292 KRESTERBROOKE LN
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Manual S Compliance Report Job: 1941A1 sf ADS Carrier <br /> Date: 6113/2018 <br /> Entire House By: Dave <br /> Bayonet Plumbing Heating and Air <br /> Project Information <br /> For: Lennar Homes <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 26302 Btuh Entering coil DB: 75.6°F <br /> Outdoor design WB: 77.3°F Latent gain: 4180 Btuh Entering coil WB: 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 30482 Btuh <br /> Indoor RH: 50% Estimated airflow: 1200 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L <br /> Actual airflow: 1200 cfm <br /> Sensible capacity: 29580 Btuh 112% of load <br /> Latent capacity: 5220 Btuh 125% of load <br /> Total capacity: 34800 Btuh 114% of load SHR: 85% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 30.8°F Heat loss: 27641 Btuh Entering coil DB: 69.7°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L <br /> Actual airflow: 1200 cfm <br /> Output capacity: 26331 Btuh 95% of load Capacity balance: 26 °F <br /> Supplemental heat required: 1310 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: n/a Model: n/a+n/a <br /> Actual airflow: 1200 cfm <br /> Output capacity: 0 kW 0% of load Temp. rise: 0 °F <br /> Meets all requirements of ACCA Manual S. <br /> -�- wrightsoft® <br /> 2018-Jun-13 13:39:35 <br /> •re.mn..wu®,c— Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 <br /> ...equipment11941 sf ADS template 3ton Carrierrup Cale=MJ8 Front Door faces: W <br />
The URL can be used to link to this page
Your browser does not support the video tag.