Laserfiche WebLink
Single. Family Dwelling <br /> Plan R&view Comments <br /> 1: F.F.E. shall be a minimum of 8" above.the road elevation and an engineered.site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the R.C. <br /> 3. :Compaction.test required if 24" or more of fill dirt is.brought.in:at any.one place: <br /> 4: .Tie in-survey required,before pouring concrete. <br /> 5.. Driveways require a R.O.W. use permit. All 4 sides of driveway.thru the sidewalk shall have <br /> expansion material:. <br /> 6. All setbacks.shall be met. <br /> 7.- All property markers shall be uncovered and marked.at time of first inspection: <br /> 8. All A.D.A:requirements shall be met. . <br /> 9. No:electric,plumbing, mechanical; or framing shall be:covered without an inspection.'and <br /> approval first. . <br /> 10. All Garages shall comply with:section R302.6.of the.F.B.C.:(Fire Separation).. <br /> 11.Appliances shall not be installed in:a location where subject to mechanical damage unless <br /> :protected by approved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall comply with section.P607.3 of the F.B.C., <br /> 13. Foundation supports-for A/C.units §hall be raised at least 3" above finished grade, M 13-08.1 .: <br /> 14. Return air in all.bedrooms. F.B.C. M,1620.4., <br /> 15. Smoke detectors are to be installed.in accordance with:R313:.1 of the F.B.C. <br /> 16; All glazing requirements are:to be in accordance with R308.4'of the F.B.C: . <br /> I T All means of egress are to be in accordance with R311,of the F.B.0 <br /> 18. `.`Green gypsum.boaid" shall riot be used as a backer in showers or tubs. R702.4.2:F.B.C. <br /> 19.'Combination-type AFCI breakers are,requited at all locations requiring an AFCI.type breaker: <br /> 20. Carbon monoxide alarins:will be required in new construction that uses-fossil-burning heating <br /> or appliances or an attached garage,: They shall be,installed in accordance with-the F.B.C. <br /> 21. All plumbing, mechanical, and electrical shall be separate from unit to.unit: This-includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C-. Codes:will be enforced. <br /> 23. Tamper- Resistant Receptacles'in accordance with 406.11 of the 2016 N.E:C . <br /> 24. In accordance-With the Land Development Code, lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25. Blower door test and blown in insulation card shall be provided before C.O. <br /> 26.A copy of the enemy cdcIs shall be with permit-at all tines. <br /> 27. Copy of final insulation report shall be.provided with.permit before.fenaL <br /> .28:No fence; pool or screen enclosure is issued with this perniz <br /> F.F.E.=Finished Floor Elevation <br /> F.B.C- Florida Building Code Oh Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.=National Electric Code(2016) <br />