My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20411
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20411
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2019 7:26:41 AM
Creation date
6/4/2019 7:26:39 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-20411
Building Department - Name
LENNAR HOMES LLC
Address
39599 DAWSON CHASE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Building and Construction Services(BCS) <br /> PA <br /> SC <br /> COUNTY FLORIDAS/ Blower Door Test Report Form <br /> Property Address: <br /> Permit#- o9,0411 Testing Company Name- SKYEMC <br /> Test Date: �z 19'"1-es'o (C� resternwb-mHASSEN KHELIFI <br /> Tester Cert#-- MY3YG6 a",,am.-904-903-1076 <br /> E,.u:hkhelifi@skyetec.com <br /> 402.4.1.2 Testing.Building envelope air tightness shall be demonstrated by Section 402.4.1.2 <br /> The building or dwelling unit shall be tested and veiffied as having an air leakage rate of not exceeding 5 air changes <br /> per hour. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals). As required by <br /> the Building Official,testing shall be conducted by an approved third pasty.A written.mpon of the results of the test <br /> shall be signed by the party conducting the test(including Agency Name)and provided to the Building Official prior to <br /> Certificate of Occupancy issuance.Testing shall be performed at any time after creation ofall scheduled penetrations of <br /> the building thermal envelope. <br /> During testing.fcheck to verify candifffon met) <br /> Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weather- <br /> stripping or other <br /> ampers including exhaust,intake,makeup air,backdraft and flue dampers shall be dosed,but not sealed beyond <br /> intended infiltration <br /> Interior doors,if installed at the time of the test,shall be open <br /> Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed <br /> ating and cooling systems,if installed at the time of the test,shall b7tumed Off <br /> Supply and return registers,if installed at the time of the test,shall be fully open <br /> Vb Building volwne(W) r) <br /> Q50 Airflow at 50 Pascal(CFM) I 2� 7 <br /> ACH5o Air changes per hour at 50 Pascal <br /> Q5o x 60=Vb ACH5o (3.0 ACH minimum) <br /> Pass I EX Fail <br /> F-1 <br /> V— <br /> ED Outside Air mechanically introduced to space(less than 3.0 ACH) <br /> I hereby certify that the above envelope leakage performance results demonstrate compliance <br /> with Florida Energy Code requirements in accordance with Section R402.4 1.2. <br /> Signature of Tester —Date <br />
The URL can be used to link to this page
Your browser does not support the video tag.