Laserfiche WebLink
Single Family Dwelhng <br /> Plan Review.Comments: <br /> 1. F.F.E. shall be a minimum:of 8" above,the road elevation and an engineered site plan. <br /> 2. Lots shall be graded.to.comply with R401.3 of theT.B.C. <br /> 3.' Compaction test required:if 241, or more of fill dirt is brought in:at ariy one place: <br /> 4: :Tie in survey required before pouring concrete. <br /> 5. Driveways.require a R:O:W.use permit.. All 4:sides of driveway.thru the sidewalk shall have <br /> expansion material: .. . <br /> 6. All setbacks.shall be met.:. <br /> 7. All property markers.-shall be uncovered and marked.at time-of first inspection: <br /> 8:. All A.D.A.requirements shall be met. <br /> 9. .No:electric;plumbing,mechanical; or frainirig shall be covered without an.inspection and <br /> approval first. <br /> 10. All Garages shall.comply_with:sectiori R302:6:of the F.B.C. (Fire Separation).. <br /> 11. Appliances:shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303.4 of.the RB:C <br /> 12:Water heaters shall comply with section P607.3 of the F.B.C. - <br /> 13. Foundation supports for.A/C.units shall be raised at least 3'.' above finished grade, M1308.1 <br /> 14.Return air in'all:bedrooms. F.B.C. M1620.4.: . <br /> 15. Smoke detectors are to be installed in accordance:with.R313' of the F.B.C. <br /> : .16:All glazing requirements are.to be in accordance with R308.4_of the.F.B.C. . <br /> 17. All means of egress are to be in accordance with R3I t of the F.B.C.. <br /> 18.-`.`Green gypsum board shall not b 'used:as a-backer iri:showers or tubs. R702.4.2.F.B.C. <br /> 19.-Combination-type'AFCI breakers are.required:at all.locations requinng.an AFCI.type breaker: <br /> 20' Carbon monoxide alarms will be requiredm n'ew:construction that uses fossil-biirning heating - -: <br /> :or appliances of an attached garage:. They shall be,installed in accordance with the F.B.C. <br /> 21. All plumbing,mechanical, and electrical shall.be separate from unit to:unit. This:-includes all. <br /> underground plumbing and electric. _ <br /> 22. All-2016 N.E.C. Codes:will be enforced:. - <br /> 23.Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 ME.0 <br /> . .24.:In accordance with the Land.Development Code, lots.shall be sodded before final at least 10 . <br /> feet around:the structure. <br /> 25. Blower door test and blown in insulation card shall be provided before C:O: . <br /> 26_A copy of the energy cacls.shall be with permit-at all times.- <br /> 27. Copy of final insulation report shall be:provided.-with:permit before rinaL . <br /> F.F.E.-Finished Floor Elevation <br /> F:B.0 Florida Building Code 6.h Edition <br /> R.O.W.-Right of Way <br /> A.D.A:-Americans with Disabilities Act _ : N.E.C.--National Electric Code (2011) . . <br />