My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20426
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20426
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2019 9:59:40 AM
Creation date
6/4/2019 7:29:27 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-20426
Building Department - Name
LENNAR HOMES LLC
Address
35994 SADDLE PALM WAY
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
T � <br /> FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT <br /> WALLS <br /> Adjacent Space Cavity Width Height Sheathing Framing Solar Belo R-%/.qflle Et In Et In Area R-Vahle Fraction Ahnr w <br /> # C)rnt In Wall Type <br /> 1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 19 8 8 157.3 ft2 0 0.600000 0 <br /> 2 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 54 8 8 437.3 ft2 0 0.600000 0 <br /> 3 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 44 8 352.0 ft2 0 0.600000 0 <br /> 4 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 40 8 320.0 ft2 0 0.600000 0 <br /> 5 N=>NE Exterior Frame-Wood Main 11 29 4 8 234.7 ft2 0.23 0.01 0 <br /> 6 W=>NW Garage Frame-Wood Main 11 15 4 8 122.7 ft2 0.23 0.01 0 <br /> 7 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 6 8 48.0 ft2 0 0.600000 0 <br /> DOORS <br /> # Ornt Door Type Space Storms U-Value Width Height Area <br /> Ft In Ft In <br /> 1 N=>NE Insulated Main None .2 3 6 8 20 ft2 <br /> 2 N=>NE Wood Main None .4 2 8 6 8 17.8 ft2 <br /> WINDOWS <br /> Orientation shown is the entered orientation => changed to Worst Case. <br /> / Wall Overhang <br /> V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening <br /> 1 N=>NE 1 Metal Low-E Double Yes 0.56, 0.3 N 32.0 ft2 6 ft 4 in 0 ft 4 in None None <br /> 2 E=>SE 2 Metal Low-E Double Yes 0.54 0.33 N 32.0 ft2 1 ft 0 in 0 ft 10 in None None <br /> 3 S=>SW 3 Metal Low-E Double Yes 0.54 0.33 N 16.0 ft2 1 ft 0 in 0 ft 10 in None None <br /> 4 S=>SW 7 Metal Low-E Double Yes 0.58 0.32 N 40.0 ft2 2 ft 0 in 0 ft 6 in None None <br /> 5 S=>SW 3 Metal Low-E Double Yes 0.54 0.33 N 69.0 ft2 1 ft 0 in 0 ft 10 in None None <br /> 6 W=>NW 4 Metal Low-E Double Yes 0.54 0.33 N 8.8 ft2 1 ft 0 in 0 ft 10 in None None <br /> GARAGE <br /> # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation <br /> 1 617ft2 617ft2 49ft 8ft 1 <br /> INFILTRATION <br /> # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 <br /> 1 Wholehouse Proposed ACH(50) .000305 1822.4 100.05 188.15 .227 6 <br /> HEATING SYSTEM <br /> # System Type Subtype Efficiency Capacity Block Ducts <br /> 1 Electric Heat Pump/ None HSPF:8.5 34.6 kBtu/hr 1 sys#1 <br /> 8/13/2018 2:51 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.