Laserfiche WebLink
-Si ng e ami y we ing <br /> Plan_Review.Comments <br /> 1: F.F:E. shall be,a minimum':of 8"above the road.elevation and an engineered.site plan. <br /> 2. Lots shall be graded,to comply with R401.3 of the F.B.C. <br /> 3. .Compaction test required.if 24 or more of fill dirt is brought in at any one place. <br /> 4: Tie in' survey required before pouring concrete. <br /> :.-5. Driveways require a R.OM. use permit: All 4 sides of driveway.thru the sidewalk shall have <br /> expansion'' enal:. <br /> 6- -All. setbacks shall be met: <br /> 7. ;Ali.property.markers shall be uncovered and marked.at time of first 'inspection. <br /> 8. A11 A:D.A. requirements shall be met.: <br /> ...9. No:electric,plumbing,mechanical; or framing shall be covered without an.inspection and <br /> approval first. <br /> 10.All Garages shall comply.with section R302:6:of the.F.B.C::(Fire Separation). <br /> 11:,Appliaiices shall'not be installed in.a location where subject to mechanical-damage:unless. <br /> protected-by approved barriers. M303.4 of the F.B:C. <br /> 12. Water heaters shalf comply with sectionT607.3 of the F.B.C. <br /> 13. Foundation supports-for A/C units shall-be raised at least 37 above finished grade. M1308.1 <br /> 14. Return air in all bedrooms. F.B.C. .M1620.4-. . <br /> 15: Smoke detectors are.to be installed in accordance with.R313:1- of the F.B.C. <br /> 16.All glazing requirements are to be-in accordance with R308.4 of the F.B.C. <br /> 17. All means,of egress are to be in:accordance with R311 of the F.B.C.. <br /> 18.-`.`Green gypsum board" shall not be used as a backer.in:showers or tubs:R702.4:2 F.B.C. <br /> 19. Combination-typeAFCIbreakers are required.at all.locations requiring an AFCI.type breaker. . <br /> 20: Carbon monoxide alarms:will be required in new-construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C: <br /> 21. All plumbing,mechanical,:and;electrical shall be separate from unit to unit: This includes all <br /> underground plumbing and electric. <br /> 22. A112016.N.E:C: Codes will be enforced.. <br /> 23:Tamper- Resistant Receptacles in,accordance with 406-.11 of the 2016 N.E:C <br /> 24:.In accordance.with the Land Development:Code;lots shall be sodded before final at least 10 . . <br /> feet around'the structure. <br /> 25. Blower door test and blown in insulation card shall-be'-provided before C..O: <br /> 26 A-copy of the enemy cdclsslzall be with permit,at all times <br /> .27.-Copy of ririal insulation report shall be:provided.with.permit before.j ozaL <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6a'Edition . <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act' . N.E.C.=National Electric Code(2011) <br />