Laserfiche WebLink
FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 3246E sf ADS Carrier Builder Name: Lennar Homes 0512 <br /> Street: 36036 Saddle Palm Way Permit office: City,of Zephyrhills <br /> City,State,Zip: FL, Permit Number: aQ 7i <br /> Owner. 'Lennar Homes Jurisdiction: 614-2W 111660 <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(3190.6 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1380.00 ft2 <br /> b.Concrete Block-Int Insul,Exterior R=4.1 1339.70 ft2 <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 470.89 ft2 <br /> 4. Number of Bedrooms 5 d.N/A R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2643.0 sgft.) Insulation Area a.Under Attic(Vented) R=30.0 2559.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 3255 b.Knee Wall(Vented) R=30.0 84.00 ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(292.6 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH:1st Floor 6 376 <br /> a. U-Factor: Dbl,6=0.56 133.33 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 275 <br /> SHGC: SHGC=0.30 <br /> b. U-Factor: Dbl,U=0.54 119.25 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.33 a.Central Unit 24.0 SEER:15.50 <br /> b.Central Unit 24.0 SEER:15.50 <br /> c. U-Factor: Dbl,U=0.58 40.00 ft2 <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00 <br /> SHGC: b.Electric Heat Pump 24.0 HSPF:9.00 <br /> Area Weighted Average Overhang Depth: 1.684 ft. <br /> Area Weighted Average SHGC: 0.315 14.Hot water systems <br /> 8. Floor Types (2559.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1880.00 ft2 b. Conservation features <br /> b.Floor over Garage R=11.0 679.00 ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.090 Total Proposed Modified Loads: 98.63 PASS <br /> ` Total Baseline Loads: 98.98 <br /> hereby certify that the plans and specifications,covered by Review of the plans and <br /> this calculation are in compliance with the Florida Energy specifications covered by this <br /> 3 .C... <br /> Code. calculation indicates complianceNz <br /> 'I with the Florida Energy Code. rrirr �% ?•�a`�, O <br /> PREPARED BY: Dave AG�l!ich Before construction is completed <br /> DATE: this building will be inspected for <br /> compliance with Section 553.908 <br /> hereby certify that this building,as designed, is in compliance Florida Statutes. .S <br /> with the Florida Energy Code. <br /> OWNER/AGENT: BUILDING OF CI <br /> DATE: DATE:, ' <br /> - Compliance requires certification by tfithi <br /> t handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. <br /> 7/25/2018 1:16 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 5 <br />