Laserfiche WebLink
Single Family Dwelling . <br /> Plan Review Comments: <br /> l: F.F.R shall'be a dnirnum.of.8" above,the road elevation and an engineered site plan. <br /> 2.. 'Lots shall be graded to comply with R401.3 of the F.B:.C: <br /> 3.: :Compaction test required if'24" or more:of fill dirt is.brought in=at any one place: . . <br /> 4: :Tie in..survey required before pouring concrete. <br /> 5.. Driveways:require a R.O.W:use permit. All 4:sides of driveway thru the-sidewalk shall have <br /> expansion material:. . <br /> 6.- All setbacks.shall be met. .' <br /> 7. All ert ma <br /> rkers arkers shall be 'uncovered and marked at time'of first inspection: <br /> p p Y . . <br /> 8:. :All A.D.A.requirements shall be meta . <br /> 9. No.electric',plumbing, mechanical;.or'fraining shall be covered without an inspection and <br /> approval first.. . <br /> 10. All Garages shall:comply with-section R302:6-of the F.B.C. (Fire Separation). <br /> 11:Appliances:shall:iiot be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303.4'ofthe F.B:C <br /> 12. Water heaters shall comply with section:P607. of the F.B.C: <br /> 13. Foundation-supports Tor A/C units shall be raised at least 3'.' above finished grade, M1308.1 <br /> 14. Return air in all.bedrooms. F.B.C. M1620.4.. <br /> 15. Smoke detectors'are to be installed:iri accordance'with R313:1 of the F.B.C. <br /> 16: All glazing requirements are.to be in accordance with R308.4:of the F.B.C. <br /> 17. All means of egress are to be in:accordaiice with R311..of the RB.C. :: <br /> 18. `.`Green gypsum board" shall not be used:as.a h ker,in:showersor tubs:R702:4:2 F.B.C. <br /> 19.Combination-type AFCI breakers are.required.at all,locations requiring.an AFCl,type breaker: <br /> 20. Carbon monoxide.alarms:will.be re aired in.-new construction that uses fossil-burnin heating <br /> ' <br /> g <br /> g <br /> or appliances or an attached garage: They shall be installed in accordance with,the F.B.C. . <br /> 21.'All plumbing, mechanical,:and.electricai shall be separate from unit-to unit: This--includes all, <br /> underground plurribing aril electric. <br /> 22.. All 2016:N.E.C. Codes.will be enforced. <br /> .23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.-C. . <br /> 24. Iri accordance with the Land Developmeiit:Code. lots.shall be sodded before final at least 10 - <br /> feet around:the structure. <br /> 25.-Blower door:test and blown in insulation card shall be provided.before C:O: <br /> 26.A copy of the energy cdclsshall be with permit at all times. <br /> 2Z. Copy ofrnal irisulation-i'enort shall bg:provided whh:PerMit before:rInab- <br /> F.F.E.-Finished Floor Elevation - <br /> F.B.C- Florida Building Code.6t'Edition <br /> R.O.W.-Right of Way <br /> A:D.A.-Americans with Disabilities-Act N.E.C.-National Electric Code (2011) <br />