Laserfiche WebLink
FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> 0514 <br /> Project Name: 2485A sf ADS Carrier Builder Name: Lennar Homes <br /> Street: 35989 Saddle Palm Way Permit Office: City of Zephyrhills <br /> City,State,Zip: FL, Permit Number: <br /> Owner: Lennar Homes Jurisdiction: 611200 <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1720.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1408.00 ftz <br /> b.Frame-Wood,Adjacent R=11.0 312.00 ftz <br /> 3. Number of units,if multiple family 1 c.N/A R= ftz <br /> 4. Number of Bedrooms 4 d.N/A R= ftz <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2443.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2443.00 ftz <br /> 6. Conditioned floor area above grade(ftz) 2443 b.N/A R= ftZ <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftZ <br /> 11.Ducts R ftz <br /> 7. Windows(207.3 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Main 6 390 <br /> a. U-Factor: Dbl, U=0.54 135.25 ftz <br /> SHGC: SHGC=0.33 <br /> b. U-Factor: Dbl,U=0.58 40.00 ftz 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 32.00 ftz <br /> SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a.Electric Heat Pump 34.6 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.193 ft. <br /> Area Weighted Average SHGC: 0.323 14.Hot water systems <br /> 8. Floor Types (2443.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> a.Slab-On-Grad6 Edge Insulation R=0.0 2443.00 ftz b. Conservation features EF:0.950 <br /> b.N/A R= ftz None <br /> c.N/A R= ftz 15.Credits Pstat <br /> Glass/Floor Area: 0.085 <br /> Total Proposed Modified Loads: 69.36 PASS <br /> Total Baseline Loads: 69.70 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �CtS.Tq" <br /> this calculation are in compliance with the Florida Energy specifications covered by this p <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. <br /> Dave AGal�icGt <br /> PREPARED BY: Before construction is completed <br /> DATE: this building will be inspected for <br /> compliance with Section 553.908 <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. <br /> with the Florida Energy Code. Y �''Orj ,• <br /> OWNER/AGENT: BUILDING OFF? <br /> FF CIAL <br /> DATE: DATE: - i <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 5.00 ACH50(R402.4.1.2). <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. <br /> 8/14/2018 9:56 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4 <br />