Single Family.Dwelling ; <br /> Plan Review Coinments <br /> 1: F.F.E. shall be a.minimum.of 8".above.the road elevation-and an' engineered site.plan. <br /> 2.. Lots shall be graded.to comply with R401.3 of the-F.B.C. <br /> 3. .Compaction test required if 24 or more.of fill dirt is brought in at any one place. <br /> 4.. :Tie in survey-required before pouring concrete. <br /> 5. Driveways require a R.O.W. use permit: All sides of driveway thru the sidewalk shall Have <br /> - expansion material... <br /> 6.. All setbacks.shall be met.; . <br /> 7. Ali.property markersshall be,uncovered and marked at time of first inspection: <br /> 8. .All A.D.A.requirements shall be met. . <br /> 9. No electric,plumbing,mechanical, or framing shall be covered without an inspection and <br /> approval first. <br /> 10. All Garages shall-comply;.with:section R302.6 of the F.B.C.-(Fire Separation).. <br /> 11.Appliances shall not be installed in.a location where subject to mechanical'damage:unless. <br /> protected by approved barriers. M303..4'of the F.B:C <br /> 12. Water heaters shall comply.with section.P607.3 of the F.B.C. <br /> 13. Foundation supports-for A/C-units shall be raised at least 3" above finished grade. M1308.1. <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors are to be 'installed in accordance with R313:.1 of the:F.B.C. <br /> 16::All glazing requirements-are to be in accordance with R308.4.of the F.B.C. . <br /> 17. All means.of egress are to be in,accordance,with R311:of the F:B.0 .: <br /> 18. `.`Green gypsum board"shall not be used.as.a backer in:showers or tubs. R702.4.2.F.B.C: <br /> 19. Combination-type AFCI breakers are required:at all.locations requiring an AFCI,type breaker: <br /> 20: Carbori monoxide alarms will be required in.riew:construction that uses fossil-burning:heating <br /> or appliances or an attached garage.:-,They shall be-installed in accordance with the F.B.C: <br /> 21. All plumbing,mechanical,:and-electrical shall.be separate from unit to unit: fihis includes all <br /> underground plumbing and electric. <br /> 22. All 2016 ME.C. Codes-Will be enforced.. <br /> 23. -Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 ME:C . <br /> 24. In accordance.with the Land:.Development:Code;lots shall be sodded before final at least 10 . . . <br /> feet around the structure. <br /> 25. Blower door test and blown in insulation card shall be provided before CO . <br /> 26 A coprof the enerzy cacls.shall be with permit at all times.: <br /> 27..-Copy of final insulation-report shall be provided with:permit before:finab . <br /> F.F.E.=Finished Floor Elevation <br /> F.B.C-Florida Building Code 6ffi Edition. <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2011) <br />