My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20429
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20429
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2019 7:31:50 AM
Creation date
6/4/2019 7:31:48 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-20429
Building Department - Name
LENNAR HOMES LLC
Address
35997 SADDLE PALM WAY
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2606B sf ADS Carrier Builder Name: Lennar Homes 0513 <br /> Street: 35997 Saddle Palm Way Permit Office: Ci%t�rQf�,ephyrhills <br /> City,State,Zip: FL, Permit Number: 2 Y <br /> Owner: Lennar Homes Jurisdiction: 61,1 e 'UMPO <br /> Design Location: FL,Tampa County: Hillsborough(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1900.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1520.00 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 380.00 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2576.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2576.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 2576 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(215.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:.Main 6 515.2 <br /> a. U-Factor: Dbl,U=0.54 159.00 ft2 <br /> SHGC: SHGC=0.33 <br /> b. U-Factor: Dbl,U=0.58 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 16.00 ft2 <br /> SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor:' N/A ft2, a.Electric Heat Pump 34.6 HSPF:8.50 <br /> SHGC: <br /> z Area Weighted Average Overhang'•Depth;- 1.744 ft. <br /> Area Weighted Average SHGC: = 0.326, 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (2576.0 sqft.) Ansulation Area <br /> EF:0.950 <br /> a.Slab-On-Grade Edge Insulation' R=0'0 2576.00 ft2 b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Total Proposed Modified Loads: 72.98 PASS <br /> Glass/Floor Area: 0.083 - Total Baseline Loads: 73.00 <br /> I hereby certify that the plans.and'specifications covered by Review of the plans and <br /> this calculation are in compliance with the Florida Energy specifications covered by this <br /> Code:, j calculation indicates compliancejv <br /> 'Dave <br /> /� G� with the Florida Energy Code. <br /> PREPARED'BY: Before construction is completed <br /> - DATE: this building will be inspected for <br /> l compliance with Section 553.908 <br /> I herebycertifythat1his building,as designed, is in comp'once Florida Statutes. x, <br /> with the Florida Energy Code. aQ4 <br /> OWNER/AGENT: BUILDING O FICIAL: <br /> DATE: DATE: <br /> - Compliance requires certification by the air.h dler unit manufacturer that the air handler enclosure qualifies as <br /> t' certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.040 Qn for whole house. <br /> 8/14/2018 9:02 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4 <br /> .i <br />
The URL can be used to link to this page
Your browser does not support the video tag.