Laserfiche WebLink
FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2606B sf ADS Carrier Builder Name: Lennar Homes 0513 <br /> Street: 35997 Saddle Palm Way Permit office: City of Zephyrhills <br /> City,State,Zip: FL, Permit Number: <br /> Owner: Lennar Homes Jurisdiction: 611200 <br /> Design Location: FL,Tampa County: Hillsborough(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1900.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1520.00 ftz <br /> b.Frame-Wood,Adjacent R=11.0 380.00 ftz <br /> 3. Number of units,if multiple family 1 c.N/A R= ftz <br /> 4. Number of Bedrooms 4 d.N/A R= ftZ <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2576.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 2576.00 ft <br /> 6. Conditioned floor area above grade(ftz) 2576 b.N/A R= ftz <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftz <br /> 11.Ducts R ftz <br /> 7. Windows(215.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 515.2 <br /> a. U-Factor: Dbl,U=0.54 159.00 ftz <br /> SHGC: SHGC=0.33 <br /> b. U-Factor: Dbl, U=0.58 40.00 ftz 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00 <br /> c. U-Factor: Dbl, U=0.56 16.00 ftz <br /> SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a.Electric Heat Pump 34.6 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.744 ft. <br /> Area Weighted Average SHGC: 0.326 14.Hot water systems <br /> 8. Floor Types (2576.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 2576.00 ftz b. Conservation features EF:0.950 <br /> b.N/A R= ftz None <br /> c.N/A R= ftz 15.Credits Pstat <br /> Glass/Floor Area: 0.083 <br /> Total Proposed Modified Loads: 72.98 PASS <br /> Total Baseline Loads: 73.00 <br /> I hereby certify that the plans and specifications covered by Review of the plans and _:011E!Sx7 <br /> this calculation-are in compliance with the Florida Energy specifications covered by this p <br /> Code. calculation indicates compliance `'�+r; ' _ ;,•� :�s+. <br /> 'Dave <br /> with the Florida Energy Code. <br /> PREPARED BY: pG{� Before construction is completed 1 <br /> DATE: this building will be inspected for J. <br /> compliance with Section 553.908 <br /> I hereby certify that this building designed,as Florida Statutes. _; <br /> with the Florida Energy Code. g , is in compliance <br /> OWNER/AGENT: BUILDING OFFICIAL <br /> DATE: DATE. - <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.040 Qn for whole house. <br /> 8/14/2018 9:02 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4 <br />