My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20430
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20430
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2019 10:00:48 AM
Creation date
6/4/2019 7:32:31 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-20430
Building Department - Name
LENNAR HOMES LLC
Address
36002 SADDLE PALM WAY
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE' FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 3246A sf ADS Carrier Builder Name: Lennar Homes 0510 <br /> Street: 36002 Saddle Palm Way Permit office: City of ZephyrhiIls <br /> City,State,Zip: FL, Permit Number: <br /> Owner Lennar Homes Jurisdiction: 611200 <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(3190.6 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1380.00 ft2 <br /> b.Concrete Block-Int Insul,Exterior R=4.1 1339.70 ft2 <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 470.89 ft2 <br /> 4. Number of Bedrooms 5 d.N/A R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2643.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2559.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 3255 b.Knee Wall(Vented) R=30.0 84.00 ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(292.6 sqft.) Description Area a.Sup:Attic,Ret: 1st Floor,AH:1st Floor 6 376 <br /> a. U-Factor: Dbl,U=0.56 133.33 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 275 <br /> SHGC: SHGC=0.30 <br /> b. U-Factor: Dbl,U=0.54 119.25 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.33 a.Central Unit 24.0 SEER:15.50 <br /> b.Central Unit 24.0 SEER:15.50 <br /> c. U-Factor: Dbl,U=0.58 40.00 ft2 <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00 <br /> SHGC: b.Electric Heat Pump 24.0 HSPF:9.00 <br /> Area Weighted Average Overhang Depth: 1.355 ft. <br /> Area Weighted Average SHGC: 0.315 14.Hot water systems <br /> 8. Floor Types (2559.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 1880.00 ft2 b. Conservation features EF:0.950 <br /> b.Floor over Garage R=11.0 679.00 ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.090 Total Proposed Modified Loads: 98.94 PASS. <br /> Total Baseline Loads: 98.98 <br /> I hereby certify that the plans and specifications covered by Review of the plans and CT S"r <br /> this calculation are in compliance with the Florida Energy specifications covered by this �'Q _ -_ 0' <br /> Code. calculation indicates compliance' <br /> with the Florida Energy Code. <br /> PREPARED BY: Dave Aupich Before construction is completed <br /> DATE: this building will be inspected for <br /> compliance with Section 553.908 *- <br /> I herebycertify that this building,as designed, is in compliance Florida Statutes. .5 <br /> fY 9� 9 P <br /> with the Florida Energy Code. Olj wrl:1�� <br /> OWNER/AGENT: BUILDING FICIAL: <br /> DATE: DATE: l " <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with ANSI/RESNETIICC 380, is not greater than 0.030 Qn for whole house. <br /> 7/25/2018 1:09 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.