Laserfiche WebLink
Manual S Compliance Report Job: 3246A sf ADS Carrier <br /> Date: 7/25/2018 <br /> lower floor By: Dave Aldrich <br /> Bayonet Plumbing Heating and Cooling- <br /> 8950 New York ave,Hudson <br /> Project • • <br /> For: Lennar Homes <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 92.3°F Sensible gain: 20013 Btuh Entering coil DB: 75.6°F <br /> Outdoor design WB: 78.8°F Latent gain: 1859 Btuh Entering coil WB: 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 21871 Btuh <br /> Indoor RH: 50% Estimated airflow: 800 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L <br /> Actual airflow: 800 cfm <br /> Sensible capacity: 20400 Btuh 102% of load <br /> Latent capacity: 3600 Btuh 194% of load <br /> Total capacity: 24000 Btuh 110% of load SHR: 85% <br /> Heating • • <br /> Design Conditions <br /> Outdoor design DB: 32.5°F Heat loss: 23670 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L <br /> Actual airflow: 800 cfm <br /> Output capacity: 18859 Btuh 80% of load Capacity balance: 33 °F <br /> Supplemental heat required: 4811 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 800 cfm <br /> Output capacity: 7.1 kW 102% of load Temp. rise: 50 °F <br /> Meets all requirements of ACCA Manual S. <br /> -wrightsoft® 2018-Jul-25 13:58:15 <br /> CC a�•�a= mow- ------ Right-Suite®Universal 2018 18.0.16 RSU05714 <br /> Page 1 <br /> ...pment\3246 sf ADS template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces: N <br />