My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20444
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20444
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2019 7:34:20 AM
Creation date
6/4/2019 7:34:18 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-20444
Building Department - Name
DR HORTON INC
Address
6756 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM 1c 405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILMN ,CONSTRUCTM <br /> Florida Department of Business and Professional Regulation - Residential.Performance Method <br /> Project Na Cali 1828 Elev D Builder Name: DRH Ex res�s�Ho es [AlStreet: U Permit Office: 1' <br /> City,State,Zip: Zep yrhilis,FL, Permit Number: ZO <br /> Owner: -3 ?y 5 4 j � l� Jurisdiction: <br /> Design Location: FL,Tampa County: �� rlda Climate Zone S) <br /> i. New construction or existing New(From Plans) 9. Wall Types(1710.2 sgft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1404.00 ft2 <br /> b.Frame-Wood,'Adjacent R=11.0 306.22 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ft2- <br /> 10.Ceiling Types (1828.0 sgft.) Insulation' Area <br /> 5. is this a worst case? Ne- a.Under Attic(Vented) R=30.0 . 1828.00 ft2• <br /> 6. Conditioned floor area above grade(ft2) 1828 b.N/A R= ft2 <br /> Conditioned floor area below grade(49 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(166.5 sgft.) Description Area a.Sup:Attic, Ret:Main,AH:Main 6 356 . <br /> a. U-Factor: Dbl,U=0.34 126.50 ft2 <br /> SHGC: SHGC=0.31' <br /> b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a. Electric Heat Pump 28.6 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 2.722 ft. <br /> Area Weighted Average SHGC: 0.317 14.Hot water systems <br /> 8. Floor Types (1828.0 sqft.) Insulation Area a. Electric Cap:50 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 . 1828.00 ft2 EF:0.950 <br /> b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> x <br /> Total Proposed Modified Loads: 61.27 ���� <br /> Glass/Floor Area: 0.091 Total Baseline,Loads: 61.29 <br /> I hereby certify that the plans and specifications covered by Review of the plans and © 114E ST,q � <br /> this calculation are in compliance with the Florida Energy specifications covered by this �+IV M <br /> I Code. calculation indicates compliance p„r`� <br /> with the Florida Energy Code. <br /> PREPARED BY: �1"tL <br /> . . .,,�,. Before construction is completed <br /> DATE: ° x-ar-fR r-� a <br /> this building will be inspected for <br /> compliance with Section 553.908 <br /> hereby certify that this building, as designed,is in compliance Florida Statutes: 5c; <br /> with the Florida Ener o . G0 <br /> OWNER/AGENT: - BUILDING OFFICIAL: <br /> DATE: 9 DATE: qnl <br /> e <br /> S3' <br /> - Compliance requires certification by the air handler unit manufacturer that the air hand enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).- <br /> Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with AN8I/RESNET/1CC 380,is not greater than 0.060 On for whole house.. <br /> 8/31/2018 10:13 AM EnergyGauge@)USA Section R405.4.1 Compliant Software- Page 1 of 4 <br />