Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall be a minimum of 8"above the road elevation and an engineered site a plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3. Compaction test required if 24"or more of fill dirt'is brought in at any one place. <br /> 4. Tie in s.urvey required before pouring concrete.. <br /> .6. Driveways require ak.O..W. use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material.- <br /> 61 All setbacks shall be met: <br /> 7. All property markers shall be uncovered and marked at time of first inspection. <br /> 8, All A.D.A, requirem-tints shall be met. <br /> 9. No electric,plumbing,mechanical,or framing shall be covered without an inspection and <br /> approval first. <br /> 10,All Garages shall comply with section R302.6 of the F.B.C,-(Fire Separatioon). <br /> 11. Appliances shall not be installed in a location where sub ed to mechanical damage unless <br /> protected by approved barriers. M303.4 of the F.B:C <br /> 12. Water heaters shall comply with section P607.3 of the FRC. <br /> 13. Foundation supports for A/C units shall be raised at least 3"above finished grade. M1308,1 <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 15, Smoke detectors are to be installed in accordance with R313.1 of the F.P.C. <br /> 16. All glazing requirements are to be in accordance with R308.4.of the F.B.C. <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18."green gypsum board shall not be used as a backer.in showers or tubs.R702.4.2 F.B.C. <br /> 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new constniction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C: <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit, This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br /> 23.Tamper:Resistant Receptacles in accordance with 406.11 of the 2016 N:E.0 <br /> 24. In accordance with the Land Development Code, lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25. Blower door test and blown in insulation card shall be provided before C.O. <br /> 26 A copy of the en=v cacls shall be with permit at all tin:es <br /> 27. Couy of vital insulation-report shall be.provided with.perozit before final: <br /> 28. No fence;.pool or screen enclosure is issued with this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />