Laserfiche WebLink
i <br /> FORM R405-2017 <br /> 6 LQMDA ENERGY EFF111 ENCY CODE FOR BMUNG CONSTRUCMN <br /> Florida Department of Business and. Professional Regulation - Residential Performance Method <br /> Project Na Aria 1672 Elev C Builder Name: DRH Express Homes <br /> `Street: Ye� rz 1 - Permit Office: ry I <br /> City,State,Zip: Zephyrhills,FL,, Permit Number: <br /> Owner: . `3_:Is4 . a�`� Jurisdiction: <br /> Design Location: FL,Tampa County: Florida Climate Zone 2) <br /> C°�X <br /> t 1. New construction or existing New(From Plans) 9. Wall Types(1658.2 sgft.) Insulation Area <br /> t <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1372.20 ft2 <br /> b.Frame-Wood,Adjacent R=i 1.0 286.00 ft2 <br /> 3. Number of units,if multiple family f c.N/A R= ft2 <br /> 4. Number of Bedrooms 3 d_N/A R= ft2 <br /> 10.Ceiling Types (1672.0 sgft.) Insulation Area <br /> 5. Is this a worst case? -No a.Under Attic(Vented) - R=30.0 1672.00 ft2 <br /> i 6. Conditioned floor area above grade(ft2) 1672 b.N/A R= ft2' <br /> I Conditioned floor area below grade(ft2) 0 c.NIA R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(182.0 sgft.) Description Area a.Sup:Attic, Ret:Main,AH:Main .6 334 <br /> f a. U-Factor: Dbl,U=0.34' 142.00 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency1 . <br /> a.Central Unit 28.6 SEER:14.00 <br /> SHGC: SHGC=0 34 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 28.6 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 4.701 ft. <br /> Area Weighted Average SHGC: 0.317 14.Hot water systems. <br /> t 8. Floor Types (1672.0 sgft.) Insulation Area a. Electric Cap:50 gallons <br /> I a.Slab-On-Grade Edge Insulation R=0.0, 1672.00 ft2 b. Conservation features EF.0.950 <br /> b.NIA R= ft2 None <br /> c.N/A R= ft2. 15.Credits Pstat <br /> Total Proposed Modified Loads: 57.45 <br /> Glass/Floor Area: 0.109 PA - <br /> Total Baseline Loads: 57.17 <br /> 1 hereby certify that the plans and specifications covered by Review of the plans and tJ Jjili <br /> t this calculation are in compliance with the Florida Energy specifications covered by this . �. , _ gyp. <br /> Code, calculation indicates compliance �ff„ <br /> with the Florida Energy Cade. <br /> i <br /> Before construction is completed <br /> PREPARED BY: __�tt��..M P <br /> j -DATE: x-3Eia this building will be inspected for <br /> compliance with Section 553.908 <br /> I hereby certify that this bui 'ng;as designed,is in compliance Florida Statutes. <br /> tl with the Florida Energ o <br /> OWNER/AGE T: BUILDING OFFICIAL: <br /> DATE: Lo DATE: . <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires.an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). <br /> 8/31/2011 8 10:32 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 4 <br />