My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20445
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20445
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2019 7:35:31 AM
Creation date
6/4/2019 7:35:29 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-20445
Building Department - Name
DR HORTON INC
Address
6764 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Job <br /> +Wrightsoft, Project Summary Daft: <br /> Entire House BY: <br /> Progressive Air-Systems, Inc Plan: Aria 4EAB 1672 <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3893 Fax:727-815-3399 License:CAC033669- <br /> .,5.a _ _ yf ^T.., < ,e .• ' <br /> xf.•: �ra' .a?: --aYe. .N-. T!•:�.,, s�'x-~F''e n"'k"x.a Le;.ti,"'.�".,. k,f.}-.'"'""i>," <br /> For: DR Horton <br /> Lot 2 Blk 11 Silverado, Zephyrhills, FL <br /> Notes: <br /> ,15 fl e 'S: <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Conditions Summer Design_Conditions <br /> Outside db 40 OF' Outside db 91 OF <br /> Inside db 70 OF Inside db 75 IF <br /> Design TD 30 OF Design TD 19 IF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing. <br /> Structure 16693 Btuh Structure 16219 Btuh <br /> Ducts 3619 Btuh Ducts - 5114 Btuh U <br /> Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br /> none <br /> Humidification 0 Btuh Blower e) 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 20312 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 21334 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 2231 Btuh <br /> Ducts 646 Btuh <br /> Central vent (0 cfm) 0 Btuh <br /> Heating Coolingq (none) <br /> Area(ft2) 1647 1647 Equipment latent load 2877 Btuh <br /> Volume(W) 14494 14494 <br /> Air changes/hour 0.26 0.14 Equipment total load 24211 Btuh <br /> Equiv.AVF(cfm) 63 34 Req.total capacity at 0.75 SHR 2.4 ton <br /> Heating Equipment Summary Cooling Equipment Summary_ <br /> Make Carrier Make Carrier <br /> Trade CARRIER Trade CARRIER <br /> Model CH14NB030****A Cond CH14NB030**"*A <br /> AHRI ref Coil FB4CNP030 - <br /> AHRI ref <br /> Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER <br /> Heating input Sensible cooling 22500 Btuh <br /> Heating output 29600 Btuh @ 470F Latent cooling 7500 Btuh <br /> Temperature rise 27 OF Total cooling 30000 Btuh <br /> Actual air flow . 1000 cfm Actual air flow 1000 cfm <br /> Air flow factor 0.049 cfm/Btuh Air flow factor 0.047 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat.ratio 0.88 <br /> Capacity balance point=31 IF <br /> Backup: . <br /> Input=6 kW, Output,=21934 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> wri htsoft4 2018-Aug-3110:33:16 <br /> ACGA Right-Suite®Universal got 17A21 RSU25554 Page 1 <br /> _..ightsoft Flies\Express homes\Aria 4EAB 1672.rup Calc=MJB House Front faces:NW <br />
The URL can be used to link to this page
Your browser does not support the video tag.