Laserfiche WebLink
FORM R405-2 017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Nam Neuville 1751 Elev D Builder Name: DRH Express H es <br /> S :V= qrk;((s <br /> tr Permit Office: <br /> City,State,Zip: Zephyr ffills,FL, V Permit Number: 2, <br /> Owner: Jurisdiction: 00D <br /> Design Location: FL,Tampa county-C. im e,(a4ne 2 <br /> 1. New construction or existing Now(From Plans) 9. Wall Types(1640.9 sqft.) Insulation Area <br /> 11 2. Single family'or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1366.40 f12 <br /> b. Frame-Wood,Adjacent R=1 1.0 274.44 f F <br /> 71 3. Number of units,if multiple family 1 c.N/A <br /> It R= ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= 112 <br /> 5. Is this a worst case? No 10.Ceiling Types (1751.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1751.00 ft2 <br /> 6. Conditioned floor area above grade(W) 1751 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0' c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> it 7. Windows(174.5 sqft.) Description Area a.Sup:Attic, Ret:Main,AH:Main 6 392 <br /> a., U-Factor: Dbl,U=0.34 134.50 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> c. U-Factor: N/A ft2 <br /> Ii SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 28.6 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.110 ft. <br /> Area Weighted Average SHGC: 0.317 14.Hot water systems <br /> a.Electric Cap:50 gallons <br /> 8. Floor Types (1751.0 sqft.) Insulation Area EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1751.00 ft2 b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Total Proposed Modified Loads: 60.36 <br /> EjGlass/Floor Area: 0.100 P A S Sh <br /> Total Baseline Loads: 60.23 <br /> I hereby certify that the plans and specifications covered by Review of the plans and <br /> fixE ST;4 <br /> 0 .4 1- <br /> this calculation are in compliance with the Florida Energy specifications covered by this - 0 <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. <br /> PREPARED BY: Before construction is completed <br /> ;I _... <br /> DATE: 8-31-18 this building will be inspected for <br /> compliance with Section 553.908 <br /> lou",as designed,is in compliance ii I hereby certify that this Florida Statutes. <br /> with the Florida Ener Cod <br /> OWNER/AGE T-7-_ BUILDING OFFW <br /> <=I- �'Q V DATE:DATE: 0 7 2010 <br /> V <br /> - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). <br /> .. Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming.duct leakage to outdoors, <br /> tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.050 Qn for whole house. <br /> 8/3112018 11:42 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 1 of 4 <br />