My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20446
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20446
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2019 7:36:34 AM
Creation date
6/4/2019 7:36:32 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-20446
Building Department - Name
DR HORTON INC
Address
6788 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT <br /> WALLS <br /> Adjacent Cavity Width Height Sheathing Framing Solar Below <br /> it-V I n,n, JO Wail T%/Pp Space R-Value Et In Et In Prnntinn Abqor Grgrie% <br /> ri 1 N=>NW Exterior Concrete Block-Int Insul Main 4.1 19 4 8 8 167.6 ft2 0 0 0.6 0 <br /> 2 E=>NE Exterior Concrete Block-Int Insul Main 4.1 43 0 8 8 372.7 ft2 0 0 0.6 0 <br /> 3 S=>SE Exterior Concrete Block-Int Insul Main 4.1 39 8 8 8 343.8 ft2 0 0 0.6 0 <br /> 4 W=>SW Exterior Concrete Block-Int Insul Main 4.1 55 8 8 8 482.4 ft2 0 0 0.6 0 <br /> 5 N=>NW Garage Frame-Wood Main 11 19 8 8 8 170.4 ft2 0 0.23 0.01 0 <br /> 6 E=>NE Garage Frame-Wood Main 11 12 0 8 8 104.0 ft2 0.23 0.01 0 <br /> ii <br /> DOORS <br /> # Ornt Door Type Space Storms U-Value Width HeightFt In Ft In Area <br /> I N=>NW Insulated Main None .4 3 6 8 20 ft2 <br /> 2 E=>NE Wood Main None .46 2 8 6 8 I7.8 ft2 <br /> WINDOWS <br /> Orientation shown is the entered orientation(=>)changed to As Built(rotated 315 degrees). <br /> Wall Overhang <br /> # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening <br /> 1 N=>NW 1 Vinyl Low-E Double Yes 0.34 0.31 N 15.5 ft2 1 ft 0 in 3 ft 0 in None None <br /> 2 N=>NW 1 Vinyl Low-E Double Yes 0.34 0.31 N 2.5 ft2 8 ft 8 in Oft I in None None <br /> 3 E=>NE 2 Vinyl Low-E Double Yes 0.34 0.31 N 31.0 ft2 1 ft 0 in 0 ft 10 in None None <br /> 4 E=>NE 2 Vinyl Low-E Double Yes 0.34 0.31 N 8.0 ft2 1 ft 0 in 0 ft 10 in None None <br /> 5 S=>SE 3 Vinyl Low-E Double Yes 0.34 0.31 N 46.5 ft2 1 ft 0 in 0 ft 10 in None None <br /> 6 S=>SE 3 Metal Low-E Double Yes 0.55 0.34 N 40.0 ft2 1 ft 0 in 1 ft6 in None None <br /> 7 W=>SW 4 Vinyl Low-E Double Yes 0.34 0.31 N 31.0 112 1 ft 0 in 0 It 10 in None None <br /> GARAGE <br /> Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation <br /> 1 426.09 ft2 426.09 ft2 49.67 ft 8.7 ft 0 <br /> INFILTRATION <br /> Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 <br /> 1 Wholehouse Proposed ACH(50) .000386 1771.1 - 97.23 182.86 .2941 7 <br /> HEATING SYSTEM <br /> System Type Subtype Efficiency Capacity Block Ducts <br /> 1 Electric Heat Pump/ None HSPF:8.2 28.6 kBtu/hr I sys#1 <br /> 8/31/2018 11:42 AM EnergyGaugeD USA Section R405.4.1 Compliant Software Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.