PWANDATORY REQUIREMENTS A (Continued) <br /> r-i R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to <br /> L_ open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or, <br /> enclosed in a room,isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements <br /> of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be <br /> fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated where it <br /> passes through conditioned space to a minimum of R-8. <br /> Exceptions: <br /> 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. <br /> 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. <br /> _J R402.4.5 Recessed fighting.- Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage <br /> between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not <br /> more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed <br /> luminaires shall be sealed with a gasket'or caulk between the housing and the interior wall or ceiling covering. <br /> R403.1 Controls. SECTION R403 SYSTEMS <br /> E] R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. <br /> F] R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls <br /> that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. <br /> R403.3.2 Seating(Mandatary) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways <br /> for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section <br /> C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. <br /> Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or <br /> (7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i),Florida Statutes,to be"substantially leak free"in <br /> accordance with Section R403.3.3. <br /> r-� R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent <br /> IJ of the design airflow rate when tested in accordance with ASHRAE 193. <br /> R403.3.3 Duct testing(Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: <br /> L 1 1 Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,including the <br /> manufacturer's air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise sealed during the test. <br /> 2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the <br /> entire system,including the manufacturer's air handler enclosure.Registers shall be taped or otherwise sealed during the <br /> test. <br /> Exceptions: <br /> 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building <br /> thermal envelope. <br /> 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. <br /> A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. <br /> IR403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. <br /> R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) <br /> or below 55°F(13°C)shall be insulated to a minimum of R-3. <br /> R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that <br /> �- caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause <br /> degradation of the material.Adhesive tape shall not be permitted, <br /> ;—} R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). Heated water circulation systems shall be in <br /> LJ accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. <br /> Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible. <br /> R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return <br /> pipe shall be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited. <br /> Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the <br /> occupancy.The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and <br /> when there is no demand for hot water. <br /> R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515.Controls for such systems <br /> -� shall automaticallyadjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance <br /> 1 9Y F 9 P F P 9 <br /> with the times when heated water is used in the occupancy. <br /> 8/31/2018 11:42 AM EnergyGauge@ USA -FBC 6th Edition(2017)Compliant Software Page 2 of 5 <br />