My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20446
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20446
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2019 7:36:34 AM
Creation date
6/4/2019 7:36:32 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-20446
Building Department - Name
DR HORTON INC
Address
6788 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Jo <br /> .�. wrightsofta Project Summary Date: <br /> Entire House By: <br /> Progressive Air Systems, Inc Dian: Neuville 1751 <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-a47-3898 Fax:727-815-3399 License:CAC033669 <br /> r t vz <br /> For: DR Horton <br /> Lot 4 Blk 11 Silverado, Zephyrhills, FL <br /> Notes: <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 40 OF Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 30 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 17189 Btuh Structure 16037 Btuh <br /> Ducts 3687 Btuh Ducts 5209 Btuh <br /> Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 20877 Btuh Use manufacturer's data y <br /> Rate/swing multipplier 1.00 <br /> Infiltration Equipment sensible load 21246 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 2301 Btuh <br /> Ducts 656 Btuh <br /> Central vent (0 cfm) 0 Btuh <br /> Heatingg Cooling (none) <br /> Area(ft2) 1740 1740 Equipment latent load 2957 Btuh <br /> Volume(ft3) 15314 15314 <br /> Air changes/hour 0.26 0.14 Equipment total load 24203 Btuh <br /> Equiv.AVF(cfm) 66 36 Req. total capacity at 0.75 SHR 2.4 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade CARRIER Trade CARRIER <br /> Model CH14NB030****A Cond CH14NB030****A <br /> AHRI ref Coil FB4CNP030 <br /> AHRI ref <br /> Efficiency. 8.2 HSPF Efficiency 11.5 EER, 14 SEER <br /> Heating input Sensible coaling 22500 Btuh <br /> Heating output 29600 Btuh @ 470F Latent cooling 7500 Btuh <br /> Temperature rise 27 OF Total cooling 30000 Btuh <br /> Actual air flow 1000 cfm Actual air flow 1000 cfm <br /> Air flow factor 0.048 cfm/Btuh Air flow factor 0,047 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.88 <br /> Capacity balance point =31 OF <br /> Backup: <br /> Input=6 kW, Output-- 19779 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> wri f tsoft <br /> � Right-Suite@ Universal 2017 17.0.21 RSU25554 2018-Aug-3111:46:20 <br /> ...rightsoft FileslExpress homes\Neuville,175i.rup Cato=MJ8 House Front faces:NW Page i <br />
The URL can be used to link to this page
Your browser does not support the video tag.