Laserfiche WebLink
Single Family Dwelling <br /> Plan Review Comments <br /> 1. F F.E, shall be a minimum- of 8"above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R40.1.3 of the F.B.C. <br /> 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. A11 setbacks shall be met: <br /> 7. All property markers shall be uncovered and marked at time of first inspection. <br /> 8. All A.' D.A. requirements shall be net. <br /> 9. No electric,plumbing,mechanical;or framing shall be covered without an inspection and <br /> approval first: <br /> 10. All Garages shall comply with section R302.6 of the F.B.C:.(Fire Separation). <br /> 11.Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303.4 of the F B.0 <br /> 12. 'Water heaters shall comply with section P607.3 of the F.B.C. <br /> 13.Foundation supports for A/C units shall be raised at least 3"above finished grade, M13.08.1 <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. <br /> 16.All glazing requirements are to be in accordance with R308.4 of the F.B.C. <br /> 17.All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum board"shall not be used as a backer.in showers or tubs. R702.4.2 F.B.C. <br /> 19. Combination-type AFCI breakers are required at all.locations requiring'an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil..-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B:C. <br /> 21. All plumbing,mechanical, and.electrical shall be separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforeed. <br /> 23.Tamper:Resistant Receptacles in accordance with-406.11 of the 2016 N.E.0 <br /> 14. hi accordance with.the Land Development Code, lots shall be sodded before final at least 10 <br /> feet around the structure: <br /> 25. Blower door test and blown in insulation card shall be provided before C.O. <br /> 26.A copy of the en=v cacls shall be with per1-nit at all times <br /> 27. Copy of final insulation report shall be.provided with Permit before final <br /> 28: No fence..pool:or screen enclosure is,issued with this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />