Laserfiche WebLink
: FORM R405-2017 <br /> Florida Department of Business and Professional Regulation Residential Performance Method <br /> 11 Project Na Hayden 2605 Elev H , Builder Name: DRH Express Homesj <br /> streef:�wa-Q��t�3 r Permit Office: I <br /> City,State,Zip: Zephyr ills,FL, Permit Number:' <br /> Owner: ?�5L4� Jurisdiction: <br /> Design Location: FL,Tampa 1� 'County: (Florida Climate Zo 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2704.0 sgft.) Insulation Area <br /> 2. Single family or multiple family Single-family <br /> a.Concrete Block-Int Insul, Exterior R=4.1 2389.10 ft2 <br /> 1 b.Frame Wood,Adjacent R=11.0 314.89 it, # <br /> ;s 3. Number of units,if multiple family 1 c.N/A R= ft2 ] <br /> 4. Number of Bedrooms 5 d.N/A R= ft2 <br /> 10.Ceiling Types (1541.0 sqft.) Insulation Area <br /> 5. Is this a worst case? No a-Under Attic(Vented) 11=30.0 1541.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 2605 b.N/A R= ft2 <br /> }' Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> t; 7. Windows(252.7 sgft.) Description Area a.Sup:Attic, Ret:2nd Floor,AH:2nd Floor 6 261 <br /> a. U-Factor: Dbl,U=0.34 212.67 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbi,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> ii SHGC. SHGC-0 34 a.Central Unit 40.0 SEER:14.00 <br /> ` c. U-Factor: N/A ft2 <br /> j SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 41.0 HSPF:8.20 <br /> t SHGC: <br /> Area Weighted Average Overhang Depth: 1.966 ft. <br /> Area Weighted Average SHGC: a.Electric Cap:50 gallons 0.315 i4.Hot water systems <br /> F� 8. FlocrTypes (1541.0 sgft.) Insulation Area EF:0.950 <br /> 'i a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ft2 b. Conservation features <br /> i b.Raised Floor R=19.0 " 437.00 ft2 None <br /> I c.N/A R- - ft2 15.Credits Pstat <br /> l4. Total Proposed Modified Loads: 84.98 <br /> Glass/Floor Area: 0.097 PASS <br /> Total Baseline Loads: 86.22 <br /> 4 i <br /> C� <br /> !hereby certify that the plans and specifications.covered by Review of the plans and �J TJiE 5 <br /> s; this calculation are in compliance with the Florida Energy specifications covered by this <br /> r Code. calculation indicates compliance <br /> with the Florida Energy Code. Y ,; O <br /> } PREPARED BY: t�21e-�„ r Before construction is completed s - "'""'•i4 '-'s <br /> ' DATE: _ s-al-l� this building will be inspected for 0 .1l' <br /> compliance with Section 553.908 <br /> Florida Statutes. <br /> I hereby certify that this bui as designed,is in compliance 1 <br /> with the Florida Energ Co <br /> /�. <br /> OWNER/AGE T: BUILDING OFFICI�y�Y f <br /> DATE: DATE: <br /> - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with,envelope leakage no greater than 7.00 ACH50(R402.4.1.2). <br /> - Compliance with'a-proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with ANSURESNET/ICC 380,'is not greater than 0.060 Qn for whole house. <br /> 8/31/2018 10:53 AM EnergyGaugeO USA Section R4.05.4.1 Compliant Software Page 1 of 5 <br />