My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20447
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20447
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2019 7:37:52 AM
Creation date
6/4/2019 7:37:50 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-20447
Building Department - Name
DR HORTON INC
Address
6776 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Wrig,htso t Project Summary Da e: <br /> Entire House By: <br /> Progressive Air Systems, inc Plan: Hayden 2605 <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> xy'.,Sv.'".:v7';1+9;:^ <br /> ;-Y,.,f 'A:3?'"**9,-�.rr['-0�,-,<;ar; :+`^.aJk> `r'�v�ro`:..�,.�'.a^h>��-i':s zear�% Ft 9 � .,k'.:,.y, ,<;k P;"'�§eu.,, ;.' :,tt:.< r: :.� �=.•' ,✓,�„` .�a;� <br /> •^g ..,� ass.': �tb'k ���.:y_a. t s''"a. �.'�=r'i�'�- ,.aa�+'�>'�'t�` 'M;':`-'z�'K=€.�f� i <br /> For: DR Horton <br /> Lot'3 Blk 11 Silverado, Zephyrhills, FL <br /> Notes: <br /> N". "�k,�'✓ h:$.L Y. ,, " +�` =�,:d".tJi'��N�,.YS`a^G+i' ' _ - � ....w. Y <br /> Weather: ' Tampa Intl AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 40 OF - Outside db 91 OF <br /> Inside db 70, OF Inside db 75 OF <br /> Design TD 30 OF, Design TD 16 OF <br /> Daily range L. <br /> Relative humidity 50 % <br /> Moisture difference 54 grllb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 22114 Btuh Structure 21050 Btuh <br /> Ducts 6590 Btuh Ducts 7 8963 Btuh. <br /> Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br /> none <br /> Humidification 0 Btuh Blower e) 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load. 28704 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration. Equipment sensible load 30013 Btuh <br /> Method Simplified Construction quality Semi-tight Latent Cooling Equipment Load Sizing <br /> Fireplaces 0 Structure 2674 Btuh <br /> Ducts 1469 Btuh <br /> Central vent(0 cfm) 0 Btuh <br /> Heating coolin (none) <br /> Area(ft2) 2659 26N Equipment latent load 4144 Btuh <br /> Volume(W) 22094 22094 <br /> Air changes/hour 0.22 0.11 Equipment total load 34157 Btuh <br /> Equiv.AVF(cfm) 81 41 Req. total capacity at 0.75 SHR_ 3.3 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier- <br /> Trade CARRIER Trade CARRIER <br /> Model CH14NB042****A Cond CH14NB042****A <br /> AHRI ref' -- Coil FB4CNP042 <br /> AHRI ref <br /> Efficiency _ 8 HSPF Efficiency 11.3 EER, 13.7 SEER <br /> Heating input Sensible cooling - 30750 Btuh <br /> Heating output 38500 Btuh @ 47OF Latent cooling 10250. Btuh <br /> Temperature rise 26 OF Total coaling 4i000. Btuh <br /> Actual airflow 1367 cfm Actual air flow 1367 cfm <br /> Air flow factor 0.048 cfm/Btuh Air flow factor 0.046 cfm/Btuh <br /> Static pressure 0.56, in H2O Static pressure 0.56 in H2O <br /> Space thermostat Load sensible heat ratio 0.88 . <br /> Capacity balance point=33 OF <br /> Backup: <br /> Input=9 kW, Output=25290 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet ail requirements of Manual J 8th Ed. <br /> ' Wt ii�llif80 <br /> .Y,--- Right-Suite�el'Universal 201 2018-Aug-31 10:54:31 <br /> 717.0.21 RSU25554 <br /> CCP. m...press hoes\Hayden 4EHB 2605-2nd fi_biock.rup, Catc=MJS House Front faces:NW Page 1 ' <br />
The URL can be used to link to this page
Your browser does not support the video tag.