Laserfiche WebLink
Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall be a minimum of 8"above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3. Compaction test required.if M'sir more of fill dirt is brought in at any one place. <br /> 4. Tie in survey required before pouring concrete.- <br /> 5. Driveways require a R.O.M. use permit. All 4 sides of driveway thrg the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met> <br /> 7. All property markers shall be uncovered and marked at time of first inspection. <br /> �. All A.D.A. requirements shall be met. <br /> 9. No electric,plumbing,mechanical,or framing shall be covered without an inspection and <br /> approval first. <br /> 10. All Garages shall comply with section R302.6 of the F.B.C..(Fire Separation). <br /> I L Appliances shall'not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303.4 of the RB.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M130$.1 <br /> 14. Return air in all bedrooms. F.B.C. Ml620.4 <br /> 15. Smoke detectors are to be installed in accordance with R313..1 of the F.B.C. <br /> 16. All glazing requirements are to be in accordance with R.308A of the F.B.C. <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum board"shall not be us.ed.as a backer.in showers or tubs. R702.4.2 F.B.C. <br /> 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in,new construction that uses fossil.-burning heating <br /> or appliances or an attached garage: They shall be installed in accordance with the F.&C: <br /> 21. All plumbing,mechanical,.and electrical shall be separate from unit to unit; This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br /> 23.Tamper:resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 . <br /> 24. In accordance with.the Land Development Code, lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25. Blower door test and blown in insulation curd shall be provided before C.O. <br /> 26 A copy ofthe engM eacls shall be with Eerruit at all times <br /> 27. Conv of final insulation report shall be 0Mvided with nertuit before.rnaL <br /> 28 No fenee,.cool.or screen enclosure is issued with this nermiz <br /> RRE.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6th Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />