Laserfiche WebLink
GENERALNOTES <br /> 1.THE PRODUCT SHOWN HEREIN CONSTRUCTED FROM DECEUNINCK FL#22300 WINFORCE DOUBLE HUNG WINDOW <br /> EXTRUDED RIGID PVC FRAMES HAS BEEN TESTED TO AAMA/WDMAICSA APPROVED CONFIGURATIONS NON-IMPACT <br /> 101/I.S.2/A440-08/11,AND MEETS THE REQUIREMENTS OF THE FLORIDA <br /> BUILDING CODE,6TH EDITION(2017)..CONFIGURATIONS NOTED AS HVHZ DESIGN <br /> APPROVED HAVE ALSO BEEN TESTED TO TAS202-94,AND ARE CONFIGURATION HVHZ PRESSURE IMPACT <br /> ACCEPTABLE FOR USE IN THE HIGH VELOCITY HURRICANE ZONE. APPROVEDRATING RATING LOCK NOTE: 1 LOCK ASSEMBLY <br /> 2.THIS PRODUCT IS NON-IMPACT AND REQUIRES THE USE OF IMPACT 54"x7T'EQUAL LITE YES +50/-50 PSF (ITEMS 23-25)ALLOWED FOR <br /> PROTECTIVE DEVICES(SHUTTERS)IN WINDBORNE DEBRIS REGIONS. 24"x7T'EQUAL LITE YES +501-50 PSF 24°X77"MAX.SIZE ONLY. ALL <br /> 3. THE DESIGN PRESSURES INDICATED IN THIS DRAWING ARE AS 45" 86"EQUAL LITE YES +50/-50 PSF OTHER CONFIGURATIONS <br /> x <br /> LIMITED BYASTM E-1300 GLASS TABLES,AND TESTED WATER AND REQUIRE 2 LOCK ASSEMBLIES <br /> STRUCTURAL PRESSURES. 53"x86"EQUAL LITE NO +40t 50 PSF NONE <br /> 4,THIS DOCUMENT ADDRESSES PRODUCT ANCHORAGE TO ACHIEVE W1 FULL SCREEN INSECT SCREEN NOTE: ALL <br /> THE INDICATED DESIGN PRESSURES AT THE INDICATED SIZES,IN THE 53"x86"EQUAL LITE NO +50/-50 PSF SIZES EXCEPT 53"X86"MAY USE <br /> CONFIGURATIONS SHOWN IN THE ELEVATIONS. INSTALL PRODUCTS W/HALF SCREEN FULL SCREEN 53 HALF SCREEN <br /> WITH MAXIMUM SHIM GAP,MINIMUM EDGE DISTANCE AND EMBEDMENT, 42 x82"ORIEL NO +501-50 PSF AT FULL DESIGN PRESSURE <br /> AND WITH FASTENER TYPE AS SHOWN IN THE DETAILS AND AS <br /> INDICATED IN TABLE 1. FOR FULL PRODUCT CONSTRUCTION DETAILS 54"MAX. <br /> SEE NCTL TEST REPORTS 210-4067-02/02A/03/03A,AND 11"MAX.ON 24"MAX.WINDOW WIDTH <br /> 210.4083-03/04/05A/05C/06B/06C. WINDOW WIDTH 6"MAX. <br /> 14"MAX.ON CENTER, <br /> 5.MINIMUM GLAZING IS INSULATING GLASS 1/8 ANNEALED+1/2"GED FROM <br /> STAINLESS STEEL INTERCEPT SPACER+118"ANNEALED,GLAZED WITH CENTER,TYP. � CORNER, TYP. I 6"MAX.FROM <br /> 6.THE 4/3 ALLOWABLE STRESS INCREASE FAC OR(SHORT-TERM 111 TYP. CORNER,TYP. <br /> INCREASE FACTOR)HAS NOT BEEN USED IN THE ANCHOR ANALYSIS -- <br /> FOR THIS SYSTEM. THE 1.6 Cd FACTOR WAS USED IN THE ANALYSIS OF <br /> ANCHORAGE INTO WOOD SUBSTRATE. I _ O O <br /> 7.THE OPENING SUBSTRATE MATERIALS(FRAMING,MASONRY,BUCKS) p y� n 2}a p <br /> AND ATTACHMENT OF BUCKS TO THE SUBSTRATE ARE BY OTHERS AND >r E M>C 0 F <br /> SHALL BE VERIFIED BY THE ARCHITECT OR ENGINEER OF RECORD OR X w ;r: ��C X �y+�W <br /> AS APPROVED BY THE AUTHORITY HAVING JURISDICTION(AHJ). Q ti �C Lu cC Z W_ <br /> BUCKING,OPENINGS,&BUCKING FASTENERS MUST BE PROPERLY 2 w ¢S Lucas <br /> DESIGNED&INSTALLED BY OTHERS IN ACCORDANCE WITH THE FBC TO io O Z It. Z a Turner <br /> TRANSFER SUPERIMPOSED LOADS TO THE STRUCTURE. WITH O 1- O co V O "' ti O 2017-12-28 <br /> MASONRY OPENINGS,WOOD BUCKS ARE OPTIONAL. of = O0 Z a O �`Z 16:26+19:00 <br /> 8.DISSIMILAR MATERIALS THAT COME INTO CONTACT SHALL BE 2 h n 0 3 H Co p <br /> COATED OR OTHERWISE PROTECTED TO PREVENT GALVANIC r XX <br /> REACTIONS. WOOD BUCKS,IF USED,SHALL BE PRESSURE TREATED, U A � N lL m <br /> WITH EITHER A TREATMENT OR COATING COMPATIBLE WITH THIS Rty°, <br /> SILLANCHOR <br /> PRODUCT. SILL ANCHOR <br /> 9.ALL ANCHORS USED SHALL BE OF A MATERIAL OR HAVE A COATING SPACING SAME AS HEAD SPACING *ar N. 58201 'i <br /> SAME AS HEAD <br /> ce <br /> COMPATIBLE WITH THE PRESSURE TREATED WOOD BUCKS AND ALL <br /> OTHER WINDOW MATERIALS. 54"x77"EQUAL LITE ELEVATION 24"x77"EQ. LITE ELEV. '°'•SrA7E Oo.•s'�,.' <br /> 10.ALL HARDWARE&FASTENERS SHALL BE IN ACCORDANCE WITH <br /> THESE DRAWINGS,OR AS APPROVED,SIGNED,AND SEALED BY A +�''SSj.,.Ok....FLORIDA REGISTERED PROFESSIONAL ENGINEER ON A SITE-SPECIFIC TABLE OF CONTENTS NORTHEAST BUILDING PRODUCTS <br /> BASIS. SHEET DESCRIPTION 4280 Aramingo Ave.,Philadelphia,PA 19124 r7� <br /> 11.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER 1 NOTES,ELEV., Ph.(215)535-7110 www.camelotwindows.com 12/27/2017 <br /> . P.E. <br /> DOCUMENT. <br /> INFILTRATION RESISTANCE OF THE INSTALLED PRODUCT SHALL BE THE CONFIG TABLE SHEET DESCRIPTION: DATE DRAWN: Lucas A.7/2017 RESPONSIBILITY OF OTHERS AND ARE NOT ADDRESSED BY THIS 2 ELEV.,GLAZING NOTES,ELEVATION 4/13/2017 FL PE#58201 <br /> 3 VERTICAL SECT. 1239 Jabara Ave. <br /> 12. FOR ADDITIONAL REQUIREMENTS SEE GENERAL ANCHOR NOTES, 4 HOR1Z.SECTIONS SCALE: NTS REV:A <br /> SHEET 4. North Port,FL 342$8 <br /> 5 BOM,PART DWGS DRAWING:FPA-WINFORCE-DH-NI SHEET: 1 OF 5 Ph.941-380-1574 <br />