Permit #
18-20457
Building Department - Name
BROWN,VICTORIA
Address
5554 11TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERALNOTES WINFORCE HORIZONTAL SLIDER WINDOW' <br /> 1.THE PRODUCT SHOWN HEREIN CONSTRUCTED FROM DECEUNINCK <br /> EXTRUDED RIGID PVC FRAMES HAS BEEN TESTED TO AAMANVDMA/CSA NON-IMPACT <br /> 101/I.S.2/A440-08/11,AND MEETS THE REQUIREMENTS OF THE FLORIDA APPROVED CONFIGURATIONS <br /> BUILDING CODE,6TH EDITION(2017). CONFIGURATIONS NOTED AS HVHZ <br /> APPROVED HAVE ALSO BEEN TESTED TO TAS202-94,AND ARE ACCEPTABLE DESIGN <br /> REQUIRED HVHZ IMPACT <br /> FOR USE IN THE HIGH VELOCITY HURRICANE ZONE. CONFIGURATION GLAZING` APPROVED PRESSURE RATING <br /> 2.THIS PRODUCT IS NON-IMPACT AND REQUIRES THE USE OF IMPACT RATING <br /> PROTECTIVE DEVICES(SHUTTERS)IN WINDBORNE DEBRIS REGIONS. 74"x63"XX 2SL TYPE A YES +50/-50 PSF <br /> 3. THE DESIGN PRESSURES INDICATED IN THIS DRAWING ARE AS LIMITED 84"x66"XX 2SL TYPE B YES +50/-50 PSF <br /> BY ASTM E-1300 GLASS TABLES,AND TESTED WATER AND STRUCTURAL PRESSURES. 104"x66"XOX EQUAL LITE TYPE A YES +50/-50 PSF <br /> 4.THIS DOCUMENT ADDRESSES PRODUCT ANCHORAGE TO ACHIEVE THE 93"x66"XOX 1/4-1/2-1/4 TYPE A SASH YES +55/-55 PSF NONE <br /> INDICATED DESIGN PRESSURES AT THE INDICATED SIZES,IN THE TYPE B FIXED <br /> CONFIGURATIONS SHOWN IN THE ELEVATIONS. 'X'INDICATES OPERABLE <br /> PANEL,'O'INDICATES FIXED PANEL. INSTALL PRODUCTS WITH MAXIMUM 104"x66"XX 2SL TYPE B NO +40/40 PSF <br /> SHIM GAP,MINIMUM EDGE DISTANCE AND EMBEDMENT,AND WITH <br /> FASTENER TYPE AS SHOWN IN THE DETAILS AND AS INDICATED IN TABLE 1. 104"x66"XOX 114-1/2-1/4 TYPE B NO +40/-40 PSF <br /> FOR FULL PRODUCT CONSTRUCTION DETAILS SEE NCTL TEST REPORTS <br /> 2104067-01/01AI01B/01C,AND 2104081-01 B/01C/02B/03B/04A/04C 'SEE GLAZING DETAILS,SHEET 2 <br /> 5.APPROVED MINIMUM GLAZING IS AS SHOWN IN GLAZING DETAILS ON <br /> SHEET 2 AND AS SPECIFIED IN ALLOWABLE CONFIGURATIONS TABLE ON INSTALLATION 74"MAX.WINDOW WIDTH <br /> THIS SHEET. FASTENER 10-1/2"MAX. 6"MAX. <br /> 6.THE 4/3 ALLOWABLE STRESS INCREASE FACTOR(SHORT-TERM INCREASE LOCATION,TYP. FROM <br /> FACTOR)HAS NOT BEEN USED IN THE ANCHOR ANALYSIS FOR THIS F ON CENTER, CORNER, <br /> SYSTEM. THE 1.6 Cd FACTOR WAS USED IN THE ANALYSIS OF ANCHORAGE I TYP• TYP, <br /> INTO WOOD SUBSTRATE. <br /> 7.THE OPENING SUBSTRATE MATERIALS(FRAMING,MASONRY,BUCKS)AND �- <br /> ATTACHMENT OF BUCKS TO THE SUBSTRATE ARE BY OTHERS AND SHALL !%` 32-5/8"MAX. <br /> BE VERIFIED BY THE ARCHITECT OR ENGINEER OF RECORD OR AS <br /> APPROVED BY THE AUTHORITY HAVING JURISDICTION(AHJ). BUCKING, o DLO,TYP. w <br /> OPENINGS,&BUCKING FASTENERS MUST BE PROPERLY DESIGNED& 0 X X m LUCBS <br /> INSTALLED BY OTHERS IN ACCORDANCE WITH THE FBC TO TRANSFER u 3: Turner <br /> SUPERIMPOSED LOADS TO THE STRUCTURE. WITH MASONRY OPENINGS, w m p 2018-03-13 <br /> WOOD BUCKS ARE OPTIONAL. w z 21:43+20:00 <br /> 8.DISSIMILAR MATERIALS THAT COME INTO CONTACT SHALL BE COATED O L <br /> OR OTHERWISE PROTECTED TO PREVENT GALVANIC REACTIONS. WOOD U H <br /> BUCKS,IF USED,SHALL BE PRESSURE TREATED,WITH EITHER A W r �- ,����"''DREl4T <br /> TREATMENT OR COATING COMPATIBLE WITH THIS PRODUCT. r,U CENsfi L;Qg!.,� <br /> a`.... <br /> , . <br /> 9.ALL ANCHORS USED SHALL BE OF A MATERIAL OR HAVE A COATING z SILL ANCHOR SPACING <br /> O �30 562Q1 :P G <br /> COMPATIBLE WITH THE PRESSURE TREATED WOOD BUCKS AND ALL OTHER SAME AS HEAD <br /> WINDOW MATERIALS. 74"x63"XX 2SL ELEVATION <br /> 10.ALL HARDWARE&FASTENERS SHALL BE IN ACCORDANCE WITH THESE O,c., <br /> DRAWINGS,OR AS APPROVED,SIGNED,AND SEALED BY A FLORIDA %,FS' <br /> REGISTERED PROFESSIONAL ENGINEER ON ASITESPECIFIC BASIS. TABLE OF CONTENTS %.S�o�;� ��� <br /> 11.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER SHEET DESCRIPTION NORTHEAST BUILDING PRODUCTS <br /> INFILTRATION RESISTANCE OF THE INSTALLED PRODUCT SHALL BE THE 1 NOTES,ELEV., 4280 Aramingo Ave.,Philadelphia,PA 19124 i <br /> RESPONSIBILITY OF OTHERS AND ARE NOTADDRESSED BY THIS CONFIG.TABLE Ph.(215)535-7110 www.camelotwindows.com 3/12/201B <br /> DOCUMENT. 2 ELEV.,GLAZING SHEET DESCRIPTION: DATE DRAWN: Lucas A.Tumer,P.E. <br /> 12. FOR ADDITIONAL REQUIREMENTS SEE GENERAL ANCHOR NOTES, 3 XOX ELEV. NOTES,ELEVATION 4/13/2017 FL PE#58201 <br /> SHEET 5. 4 VERTICAL SECT. SCALE 1239 Jabara Ave. <br /> : NTS REV:B <br /> 5 HORIZ.SECTIONS North Port,FL 34288 <br /> 6 BOM,PART DWGS DRAWING:FPA-WINFORCESL-NI SHEET: 1 OF 6 Ph.941-380-1574 <br />