Laserfiche WebLink
Single Family Dwelling <br /> Plan Review Comments <br /> 1: F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3. Compaction test required if_2;4"or more of fill dirt is brought in at any one place. <br /> 4; Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7. All property markers shall be uncovered and marked at time of first inspection. <br /> 8. All A.D.A. requirements shall be met. <br /> 9. No electric, plumbing, mechanical, or framing shall be covered without an:inspection and <br /> approval first. <br /> 10. Ail Garages shall comply with section R302.6 of the F.B.C..(Fire Separation). <br /> I Appliances shall not be installed in a location where subject to mechanical"damage unless <br /> protected by approved barriers. M303.4.of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished_ grade. M13:08.1 <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. <br /> 16. All.glazing requirements are to be in accordance with R308.4.of the F.B.C. <br /> 17. All means.of egress are to be in accordance with R311 of the F.B.C. <br /> 18: "Green gypsum board"shall riot be used as a backer in.showers or-tubs. R702.4.2 F.B.C. <br /> 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil=burning heating <br /> or appliances or an attached garage: They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to.unit. This includes all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C.: Codes will be erif fed. <br /> 23. Tamper= Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code, lots shall be sodded before final at least 10 <br /> feet around the structure: <br /> 25. Blower door test and blown in insulation card shall be'provided before C.O. <br /> 26..A copy of the enerey eacls shall be with Permit at all times. <br /> 27 Copy of final hisulation report shall be.-provided with perinit before.LinaL <br /> 28:No fence,pool or screen enclosure is.issued with this vermin <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6th Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />