My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20517
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20517
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2019 7:47:42 AM
Creation date
6/4/2019 7:47:40 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-20517
Building Department - Name
LENNAR HOMES LLC
Address
2995 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�0-�- S-5 --�[ ;L65 , ---� ��� <br /> Jet Stream° Ultra Blowing Wool Insulation kNAU mo <br /> ���UL J <br /> Attic and Cavity Wall Card a\c �l S i V I ou j d e�� '-� i (O UJ iPJf+n1e{0 1Av2 e�1er(e t <br /> Batts and Blankets Equipment Required <br /> When installed in accordance with the manufacturer's It is recommended that a pneumatic blowing machine and a corrugated hose with a minimum W internal corrugation,a minimum length <br /> recommendations,Knauf Insulation batts and blankets will of 150'.Coils in the hose should not be less than 36"in diameter.Acceptable material feed rate is 5-35 lbs/minute.Recommended feed <br /> provide the full R-value. rate is 15-25 lbs/minute. <br /> R-Value* Minimum Thickness Thermal Performance(Sidewall and Attic Application) <br /> To obtain an The stated thermal resistance(R-value)is provided by installing in accordance with the manufacturer's instructions.Failure to install the <br /> insulation resistance Installed insulation should required number of bags per 1,000 square feet and exceeding the maximum square feet of coverage per bag as recommended by the label <br /> (R-value)of: not be less than: will result in lower installed R-values.Field blending of this product with other loose fill insulations is not recommended by the manufacturer. <br /> R-49 13.75" Cavity Wall Bag Net Weight-Nominal 32 lbs.,Minimum 31 Ills. <br /> R-38HD 10.25" <br /> R-38 12.00" R-Value* Bags per 1000 SF Maximum Net Minimum <br /> To obtain an The number of bags Coverage per Bag Weight per SF <br /> R-30HD 8.25" insulation per 1,000 square feet Contents of this The weight per square <br /> R-30 10.00" Cavity resistance of net area should not bag should not feet of installed insulation <br /> R-26 9.00" Framing Depth of: Density be less than: cover more than: should not be less than: <br /> R-22 6.50" 2"x 4" 3.50" R-15 1.8 lbs./cu.ft. 16.4 bags 61.0 sq.ft. 0.525 lbs. <br /> R-21HD 5.50" 2"x 6" 5.50" R-23 1.8 lbs./cu.ft. 25.8 bags 38.8 sq.ft. 0.825lbs. <br /> R-19 6.25... 2"x 8" 7.25" R-31 1.8 lbs./cu.ft. 34.0 bags 29.4 sq.ft. 1.088 lbs. <br /> R-15HD 3.50" <br /> R-13 3.50" 2"x 10" 9.25" R-39 1.8 lbs./cu.ft. 43.4 bags 23.1 sq.ft. 1.388 lbs. <br /> R-11 3.50" R means resistance to heat flow.The higher the R-value,the greater the insulating power.To get the marked R-value,it is essential that this insulation be installed property. <br /> R-8 2.50° � <br /> R-18 in a 5.5•cavity.Conforms to ASTM C 62.and Federal Open Attic Application Bag Net Weight-Nominal 32 lbs.,Minimum 31 lbs. <br /> Specification HH-1-521F. . I Minimum <br /> Bags/ Maximum Minimum Initial Settled <br /> Framing Adjustment 1,000 SF Coverage Weight Installed Thickness** <br /> To compensate for framing members,the number of bags per The number of bags/ Contents of this The weight/SF Thickness Contents of this <br /> 1,000 sq.ft.of area to be insulated should be as shown below. R-Value* 1,000 SF of net area bag should not of installed Installed insulation bag should <br /> Ba s/MSF Ba S/M$F To obtain an insulation should not be less cover insulation should not should not be less not cover more <br /> 9 9 resistance(R-Value)of: than: more than: be less than than: than: <br /> Joist 16"O.C. 24"O.C. R-60 29.7 33.6 SF .952lbs. 19.750' 19.750" <br /> R-Value Dimensions Framing Framing <br /> 2x4 29.2 29.4 R-49 23.5 42.5 SF .753 lbs. 16.375" 16.375" <br /> R-60 2x6 28.9 29.1 R44 20.9 47.8 SF .670 lbs. 14.875" 14.875" <br /> 2x8 28.6 28.9 R-38 17.8 56.2 SF .569 lbs. 13.000" 13.000" <br /> 2x4 23.0 23.2 R-30 13.6 73.3 SF .437 lbs. 10.375' 10.375" <br /> R-49 2x6 22.7 22.9 R-26 11.8 85.0 SF .377 lbs. 9.125" 9.125" <br /> 2x8 22.4 22.7 R-22 9.8 102.2 SF .313 lbs. 7.750" 7.750" <br /> 2x4 20.4 20.6 <br /> R-44 2x6 20.1 20.3 R-19 8.4 119.3 SF .268 lbs. 6.750" 6.750" <br /> 2x8 19.8 20.1 R-13 5.7 175.3 SF .183 lbs. 4.750" 4.750' <br /> 2x4 17.3 17.4 R-11 4.7 210.8 SF .152 lbs. 4.000" 1 4.000. <br /> R-38 2x6 17.0 17.2 Bag Net Weighl-Nominal321bs.,Muumum 31 lbs. <br /> 2x8 16.7 17.0 coverage and installation data were determined using a Volu-Mat&11 blaring machine in third gear with 13'gate opening,2.0 psi air pressure and 150'or T imemaflyterugated hose. <br /> This product conforms to the performance requirements of ASTM C 764,Type I,and cancelled Federal Specification HH-1-1030B,Type I,Gass B.R-values are determined in accordance with C 687 and C 518.' <br /> 2x4 13.2 13.3 "R'means resistance to heat flow.The higher the R-value,be greater the insulating power.To get the marked R-value,Ills essential that this insulation be Installed properly.If you do it yourself,gel insbuc- <br /> R-30 2x6 12.9 13.1 lions and follow them carefully.Instructions do not came wth this package. <br /> "Based on Third Party 2-year settling study,the predicted settlement over a 20-year period would be 1 percent or less.This amount of setrfing is thermally insignifuanL Therefore,the installed and settled <br /> 2x8 12.6 12.9 thicknesses are effectively the same. <br /> 2x4 11.3 11.4 VNo-Matiell is a registered trademark of Unisul. <br /> R-26 2x6 11.0 11.2 Builder's Insulation Statement it <br /> 2x8 10.8 11.0 Jet Stream Ultra has been installed in conformance with the included recommendations to provide a thermal resistance of... <br /> 2x4 9.3 9.5 R-Value Thickness <br /> R-22 2x6 9.1 9.3 Attic Area R- at Inches <br /> 2x8 8.8 9.1 Sloped Ceilings R- at Inches <br /> 2x4 7.9 8.1 Walls R- at Inches <br /> R-19 2x6 7.7 7.9 <br /> 2x8 7.4 7.7 Floors(over an unheated crawl space) R- at Inches <br /> 2x4 5.3 5.4 Crawl Space Perimeter R- at Inches <br /> R-13 2x6 5.0 5.2 Date Installed <br /> 2x8 4.8 5.0 Blown iAtion has been installed in conformance with the above recoT! n on provide an R-value of <br /> 2x4 4.3 4.4 R- ((JJ'' using �bags of this insulation to cover /J square feet of area <br /> R-11 2x6 4.1 4.3 at a minimum thickness of inches. <br /> 2x8 3.8 4.1 <br /> lllr�fM uL E.virenment Insulation Contractor(signalur�m <br /> GREENGUARD Gold" 66�^ <br /> Rn.ul lmul.lion building imut"eon ldd d i, Company /`� j� /� (7,�)1� �� <br /> Ul Environment GREENG ARD Grid N- p g"® ( QS fit: / <br /> Ul E.wi-ern v.hdmed to be fmmold.hyd.Ire. !/ <br /> UL Environment GREENGUARD Home Builder(signature) <br /> 0 cortification Program"' <br /> Pmduer me cer,6ed ro U1 Envimnmem <br /> GREENGUARD>I-d.rdr for low ch.mi.1 Company Date <br /> r into i.d-air during produce ur"go. <br /> For more Inlorm.lion,viril ul corn/gg. <br /> The coverage information on this Attic/Sidewall card applies to the entire United States(including Minnesota). <br /> www.knaufinsulation.us 1 Knauf Insulation,Inc. One Knauf Drive,Shelbyville,IN 46176 Tel:(800)825-4434 ext.8300 FAX:(317) 8-3675 <br /> ©2015 Knauf Insulation,Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.