Laserfiche WebLink
Building and Construction Services(BCS) <br /> PASC <br /> COUNTY FLORIDA sower Door Test Report Form <br /> OPEN SPACES. MBktLVT PLACES. <br /> Property Address: 3003 114 6-lu n � /VL/ Unit#: <br /> Permit#: �cy ) \/C Testing Company Name: ^ <br /> Test Date: '3 / gcp_/ qo Tester Name: ' 9 a S�G A 1 <br /> Tester Cert#: A r1(v�u�v oC� Contact Phone: T7,1 w <br /> Email: <br /> 402.4.1.2 Testing.Building envelope air tightness shall be demonstrated by Section 402.4.1.2 <br /> The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes <br /> per hour. Testing shall be_conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals).As required by <br /> the Building Official, testing shall be conducted by an approved third party. A written report of the results of the test <br /> shall be signed by the party conducting the test( including Agency Name) and provided to the Building Official prior <br /> to Certificate of Occupancy issuance. Testing shall be performed at any. time after creation of all scheduled <br /> penetrations of the building thermal envelope. <br /> Dur' g testing:(check to verify condition met) <br /> Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended <br /> w ther-stripping or other <br /> Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond <br /> i tended infiltration <br /> I terior doors,if installed at the time of the test,shall be open <br /> E terior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed <br /> H ting and cooling systems, if installed at the time of the test,shall be turned off <br /> Supply and return registers, if installed at the time of the test,shall be fully open <br /> Vb Building volume(ft3) _ e2 l� 3 7 , 5 <br /> Q50 Airflow at 50 Pascal(CFM) _ I <br /> ACH5o Air changes per hour at 50 Pascal <br /> Q5o x 60-Vb = "1 F ACH5o (3.0 ACH minimum) <br /> Pass Fail ❑ <br /> ❑Outside Air mechanically introduced to space(less than 3.0 ACH) <br /> I hereby certify that the above envelope leakage performance results demonstrate compliance <br /> with Florida Energy Code requirements in accordance with Section R402.4.1.2. <br /> Signature of Tester Date <br />